The DOI matches its Crossref record.
Muscle artifacts in the sleep EEG: Automated detection and effect on all‐night EEG power spectra
Abstract
Owing to the use of scalp electrodes in human sleep recordings, cortical EEG signals are inevitably intermingled with the electrical activity of the muscle tissue on the skull. Muscle artifacts are characterized by surges in high frequency activity and are readily identified because of their outlying high values relative to the local background activity. To detect bursts of myogenic activity a simple algorithm is introduced that compares high frequency activity (26.25–32.0 Hz) in each 4‐s epoch with the activity level in a local 3‐min window. A 4‐s value was considered artifactual if it exceeded the local background activity by a certain factor. Sensitivity and specificity of the artifact detection algorithm were empirically adjusted by applying different factors as artifact thresholds. In an analysis of sleep EEG signals recorded from 25 healthy young adults 2.3% (SEM: 0.16) of all 4‐s epochs during sleep were identified as artifacts when a threshold factor of four was applied. Contamination of the EEG by muscle activity was more frequent towards the end of non‐REM sleep episodes when EEG slow wave activity declined. Within and across REM sleep episodes muscle artifacts were evenly distributed. When the EEG signal was cleared of muscle artifacts, the all‐night EEG power spectrum showed significant reductions in power density for all frequencies from 0.25–32.0 Hz. Between 15 and 32 Hz, muscle artifacts made up a substantial part (20–70%) of all‐night EEG power density. It is concluded that elimination of short‐lasting muscle artifacts reduces the confound between cortical and myogenic activity and is important in interpreting quantitative EEG data. Quantitative approaches in defining and detecting transient events in the EEG signal may help to determine which EEG phenomena constitute clinically significant arousals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
O'Reilly, C., Gosselin, N., Carrier, J., & Nielsen, T. (2014) · Journal of Sleep Research · doi:10.1111/jsr.12169 · Cited by 356
Beta EEG activity and insomnia
Perlis, M. L., Merica, H., Smith, M. T., & Giles, D. E. (2001) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0151 · Cited by 346
Race and Financial Strain are Independent Correlates of Sleep in Midlife Women: The SWAN Sleep Study
(2009) · Sleep · doi:10.5665/sleep/32.1.73 · Cited by 326
Symptoms of Stress and Depression as Correlates of Sleep in Primary Insomnia
Hall, M., Buysse, D. J., Nowell, P. D., Nofzinger, E. A., Houck, P., Reynolds, C. F., & Kupfer, D. J. (2000) · Psychosomatic Medicine · doi:10.1097/00006842-200003000-00014 · Cited by 303
Self-citation
Metadata
- Authors
- BRUNNER, D., VASKO, R., DETKA, C., MONAHAN, J., REYNOLDS III, C., & KUPFER, D.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 5
- Issue
- 3
- Pages
- 155-164
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2092795611
- Cited by
- 172
- References
- 0
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle artifacts in the sleep EEG: Automated detection and effect on all‐night EEG power spectra. https://app.cochat.ai/papers/10.1046/j.1365-2869.1996.00009.x
- The paper
- BRUNNER, D., VASKO, R., DETKA, C., MONAHAN, J., REYNOLDS III, C., & KUPFER, D. (1996). Muscle artifacts in the sleep EEG: Automated detection and effect on all‐night EEG power spectra. Journal of Sleep Research. https://doi.org/10.1046/j.1365-2869.1996.00009.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.