Prediction of sleep‐disordered breathing by unattended overnight oximetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Between January 1994 and July 1997, 793 patients suspected of having sleep‐disordered breathing had unattended overnight oximetry in their homes followed by laboratory polysomnography. From the oximetry data we extracted cumulative percentage time at S a O 2 < 90% (CT 90) and a saturation variability index (ΔIndex, the sum of the differences between successive readings divided by the number of readings – 1). CT 90 was weakly correlated with polysomnographic apnea/hypopnea index (AHI), (Spearman 𝓅=0.36, P< 0.0001) and with ΔIndex (𝓅=0.71, P< 0.0001). ΔIndex was more closely correlated with AHI (𝓅=0.59, P< 0.0001). In a multivariate model, only ΔIndex was significantly related to AHI, the relationship being AHI=18.8 ΔIndex +7.7. The 95% CI for the coefficient were 16.2, 21.4, and for the constant were 5.8, 9.7. The sensitivity of a ΔIndex cut‐off of 0.4 for the detection of AHI≥15 was 88%, for detection of AHI≥20 was 90% and for the detection of AHI≥25 was 91%. The specificity of ΔIndex ≥0.4 for AHI≥15 was 40%. In 113 further patients, oximetry was performed simultaneously with laboratory polysomnography. Under these circumstances ΔIndex was more closely correlated with AHI (𝓅=0.74, P< 0.0001), as was CT 90 (𝓅=0.58, P< 0.0001). Sensitivity of ΔIndex ≥0.4 for detection of AHI≥15 was not improved at 88%, but specificity was better at 70%. We concluded that oximetry using a saturation variability index is sensitive but nonspecific for the detection of obstructive sleep apnea, and that few false negative but a significant proportion of false positive results arise from night‐to‐night variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The role of polysomnography in the differential diagnosis of chronic insomnia
(1988) · American Journal of Psychiatry · doi:10.1176/ajp.145.3.346 · Cited by 93
Cited by
(2006) · Anesthesiology · doi:10.1097/00000542-200605000-00026 · Cited by 1,188
(2014) · Anesthesiology · doi:10.1097/aln.0000000000000053 · Cited by 676
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
Real-time sleep apnea detection by classifier combination
Xie, B., & Minn, H. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188299 · Cited by 294
“General physiological properties of the subjects are listed in Table I while a more detailed description can be found online [22].”
Background
Metadata
- Authors
- OLSON, L. G., AMBROGETTI, A., & GYULAY, S. G.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 1999-03
- Volume
- 8
- Issue
- 1
- Pages
- 51-55
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2089180834
- Cited by
- 76
- References
- 1
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of sleep‐disordered breathing by unattended overnight oximetry. https://app.cochat.ai/papers/10.1046/j.1365-2869.1999.00134.x
- The paper
- OLSON, L. G., AMBROGETTI, A., & GYULAY, S. G. (1999). Prediction of sleep‐disordered breathing by unattended overnight oximetry. Journal of Sleep Research. https://doi.org/10.1046/j.1365-2869.1999.00134.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.