Umbilical cord blood lactate in normal infants: Comparison between two methods of measurement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives: Firstly, to determine the accuracy of the Radiometer ABL 625 lactate electrode (Radiometer Medical Pty Ltd, Nunawading, Victoria, Australia) by comparing the lactate values obtained by this method to those obtained with the Hitachi 917 lactate analyser (Boehringer Mannheim Corporation, Charlottetown, Prince Edward Island, Canada). Secondly, to determine the effect of delay in measurement on blood lactate levels. Methodology: Umbilical venous (UCV) blood samples were obtained from healthy term infants delivered vaginally. Lactate levels were measured with the Radiometer ABL 625 lactate electrode in the Neonatal Intensive Care Unit, Westmead Hospital and with the Hitachi 917 lactate analyser in 49 paired samples. In addition 26 UCV blood samples were placed in ice slurry and a further 26 samples at room temperature and blood lactate was measured at 5‐min intervals for 30 min to determine the change of lactate levels with time. Results: The lactate levels obtained from the Radiometer ABL 625 lactate electrode were consistently lower than the levels obtained from the Hitachi 917 lactate analyser (mean difference – 0.24), but the correlation was high (r = 0.97). The blood lactate levels increased at the rate of 0.012 mmol/L per min if the blood was left at room temperature. The lactate levels remained stable for 20 min if the blood was placed in ice slurry. Conclusion: The Radiometer ABL 625 lactate electrode was easy to use and there was high correlation with the values obtained by the standard laboratory method. The blood specimen must be place in an ice slurry if a delay in analysis is anticipated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Wiberg, N., Källén, K., & Olofsson, P. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01708.x · Cited by 121
Olofsson, P. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.001 · Cited by 104
Wiberg, N., Källén, K., Herbst, A., Åberg, A., & Olofsson, P. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01707.x · Cited by 57
Armstrong, L., & Stenson, B. (2006) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2005.086744 · Cited by 45
Metadata
- Authors
- Sinn, J., Lloyd, J., Todd, D., Lazarus, R., Maesel, A., & John, E.
- Venue
- Journal of Paediatrics and Child Health
- Publisher
- Wiley
- Published
- 2001-02-11
- Volume
- 37
- Issue
- 1
- Pages
- 24-27
- ISSN
- 1034-4810 (ISSN-L)
- 1440-1754
- OpenAlex
- W1980443500
- Cited by
- 14
- References
- 1
- FWCI
- 0.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.