Effect of delayed sampling on umbilical cord arterial and venous lactate and blood gases in clamped and unclamped vessels
Open accessAbstract
Background: Cord blood lactate at birth is a marker of antenatal hypoxia, and is comparable to pH as a prognostic tool. Objective: To determine, by a prospective observational study, the effect of delayed sampling from arteries and veins that were double clamped to isolate the blood from the placenta (clamped), and from vessels that were not isolated from the placenta (unclamped). Methods: Paired samples taken from clamped and unclamped vessels at 0, 20, 40, and 60 minutes were analysed for lactate, base excess, pH, and P co 2. Data were analysed as the change from time 0 at 20, 40, and 60 minutes. Results: Thirty eight placentas of infants delivered by elective caesarean section were studied. Arterial samples were taken from 20 placentas, and venous samples from 18 placentas. Arterial and venous lactate was significantly higher than at time 0 by 20 minutes in both clamped and unclamped vessels. Changes in unclamped vessels were greater than in clamped vessels. The pH remained unchanged over 60 minutes in clamped vessels, but changed significantly in unclamped vessels. Base excess changed significantly in both clamped and unclamped vessels. Conclusions: Cord blood samples taken after 20 minutes delay are unreliable for lactate measurement, even if the vessel has been doubly clamped to isolate the blood from the placenta. Current guidelines that state that blood can be sampled from a clamped cord for up to one hour after delivery should not apply to the interpretation of lactate or base excess. Delayed sampling from unclamped cords is very unreliable.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In double-clamped cords, the arterial lactate concentration increases linearly with time, and a 10-minute delay of analysis will result in an approximately 0.6 mmol/L higher value, irrespective of mode of delivery and initial value.
“In double-clamped cords, the arterial lactate concentration increases linearly with time, and a 10-minute delay of analysis will result in an approximately 0.6 mmol/L higher value, irrespective of mode of delivery and initial value.69,71”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [69]
Table 2 reports a mean arterial lactate increase of 1.2 mmol/L after 20 minutes in double-clamped cords, consistent with an approximate rate of 0.6 mmol/L per 10 minutes; the discussion describes the change as linear. But the study measured delayed sampling at 20-minute intervals, not a 10-minute delay in analysis. Its participants delivered by elective caesarean section and were metabolically normal at birth, so it does not establish the result irrespective of delivery mode or initial value. (LLM, conf=0.90)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Association between blood lactate and acid-base status and mortality in ventilated babies
Deshpande, S. A., & Platt, M. W. (1997) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.76.1.f15 · Cited by 174 · see citing works
Clinical value of a single postnatal lactate measurement after intrapartum asphyxia
da Silva, S., Hennebert, N., Denis, R., & Wayenberg, J. (2000) · Acta Paediatrica · doi:10.1111/j.1651-2227.2000.tb01334.x · Cited by 115 · see citing works
Routine measurements of umbilical artery lactate levels the prediction of perinatal outcome
Westgren, M., Divon, M. Y., Horal, M., Ingemarsson, I., Kublickas, M., Shimojo, N., & Nordström, L. (1995) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(95)90627-4 · Cited by 104 · see citing works
A practical approach to umbilical artery pH and blood gas determinations.
Duerbeck, N. B., Chaffin, D. G., & Seeds, J. W. (1992) · PubMed · Cited by 56 · see citing works
Cheung, P., Etches, P. C., Weardon, M. E., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00030 · Cited by 46 · see citing works
Chou, Y., Yau, K. T., & Wang, P. (1998) · Acta Paediatrica · doi:10.1111/j.1651-2227.1998.tb01744.x · Cited by 46 · see citing works
Is fetal acidosis in the human fetus maternogenic during labor? A reanalysis
Piquard, F., Schaefer, A., Dellenbach, P., & Haberey, P. (1991) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1991.261.5.r1294 · Cited by 45 · see citing works
Groenendaal, F., Lindemans, C. A., Uiterwaal, C. S. P. M., & de Vries, L. S. (2003) · Neonatology · doi:10.1159/000068927 · Cited by 41 · see citing works
Effect of delays in collection or analysis on the results of umbilical cord blood measurements
SYKES, G. S., & MOLLOY, P. M. (1984) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1984.tb03676.x · Cited by 27 · see citing works
Cheung, P., Robertson, C. M. T., & Finer, N. N. (1996) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.74.1.f47 · Cited by 27 · see citing works
Sequential changes in placental blood gases and pH during the hour following delivery.
Hilger, J. S., Holzman, I. R., & Brown, D. R. (1981) · PubMed · Cited by 22 · see citing works
Umbilical cord blood lactate in normal infants: Comparison between two methods of measurement
Sinn, J. K. H., Lloyd, J., Todd, D., Lazarus, R. M., Maesel, A., & John, E. (2001) · Journal of Paediatrics and Child Health · doi:10.1046/j.1440-1754.2001.00579.x · Cited by 13 · see citing works
Umbilical cord blood gas analysis; a comparison of two simple methods of sample storage
Owen, P., Farrell, T. J., & Steyn, W. (1995) · Early Human Development · doi:10.1016/0378-3782(95)01640-o · Cited by 11 · see citing works
A Technique for Serial Sampling of Umbilical Artery Blood at Birth
Ackerman, B. D., Sosna, M. M., & Ullrich, J. R. (2009) · Biology of the Neonate · doi:10.1159/000240487 · Cited by 9 · see citing works
Chou, Y., Yau, K.-I. T., & Pj, W. (1998) · Acta Paediatrica · doi:10.1080/080352598750013851 · Cited by 5 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- ACOG technical bulletin. Umbilical artery blood acid-base analysis. Int J Gynaecol Obstet 1996;52:305-10.
Cited by
Sorted by citations
Use of umbilical cord blood gas analysis in the assessment of the newborn: Table 1
Armstrong, L., & Stenson, B. J. (2007) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2006.099846 · Cited by 222 · see citing works
Self-citationOlofsson, P. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.001 · Cited by 104 · see citing works
Impact of Delayed Arterial Cord Blood Sampling for Lactate Assay
Dessolle, L., Lebrec, J., & Daraï, E. (2009) · Neonatology · doi:10.1159/000165378 · Cited by 17 · see citing works
- Authors
- Armstrong, L., & Stenson, B.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- Corresponding author
- Armstrong, L
- ORCID
- Armstrong, L
- Venue
- Archives of Disease in Childhood - Fetal and Neonatal Edition
- Publisher
- BMJ
- Published
- 2006-04-25
- Volume
- 91
- Issue
- 5
- Pages
- F342-F345
- ISSN
- 1359-2998 (ISSN-L)
- 1468-2052
- PMC
- PMC2672835
- OpenAlex
- W2168655168
- Cited by
- 45
- References
- 16
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 4 · 2021: 2 · 2020: 7 · 2019: 2 · 2018: 4 · 2017: 2 · 2016: 3 · 2015: 3 · 2014: 1 · 2013: 1 · 2012: 1
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Archives of Disease in Childhood Fetal & Neonatal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal and fetal brain pathology
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
- Keywords
- umbilical cord clamping, antenatal hypoxia, base excess, blood pH, umbilical artery, umbilical vein, placental blood, cordocentesis, cesarean section
- MeSH terms
- Acid-Base Equilibrium, Blood Specimen Collection, Carbon Dioxide, Constriction, Fetal Hypoxia, Fetal Blood, Humans, Hydrogen-Ion Concentration, Infant, Newborn, Partial Pressure, Prospective Studies, Time Factors, Umbilical Arteries, Umbilical Veins, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review