CoChat

Identification of the target neuronal elements in electrical deep brain stimulation

Holsheimer, Jan, Demeulemeester, Hilde, Nuttin, Bart, de Sutter, Paul · 2000 · European Journal of Neuroscience
Cited by 128

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The aim of this study is to identify the primary neuronal target elements in electrical deep-brain stimulation, taking advantage of the difference in strength-duration time constant (tau(sd)) of large myelinated axons ( approximately 30-200 micros), small axons ( approximately 200-700 micros) and cell bodies and dendrites ( approximately 1-10 ms). Strength-duration data were measured in patients suffering from Parkinson's disease or essential tremor and treated by high-frequency stimulation in the ventral intermediate thalamic nucleus or the internal pallidum. Threshold voltages for the elimination of tremor were determined at various pulsewidths and a pulse rate of 130 pulses per second. The tau(sd) was calculated using Weiss's linear approximation. Its mean value was 64.6+/-25.4 micros (SD) for the thalamic nucleus and 75.3+/-25.5 micros for the internal pallidum. Corrections to the mean values were made because the tau(sd) values were based on voltage-duration measurements using polarizable electrodes. Apart from this systematic error, a resolution error, due to the relatively large increment steps of the pulse amplitude, was taken into account, resulting in mean tau(sd) estimates of 129 and 151 micros for the thalamic nucleus and the internal pallidum, respectively. It is concluded that the primary targets of stimulation in both nuclei are most probably large myelinated axons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9568.2000.01306.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter

    Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492 · cited 5×

    “…GPi are large myelinated axons, because these axons are known to have a tsd not exceeding » 0.2 ms, whereas smaller axons have values of » 0.2±0.7 ms and cell bodies, dendrites and small unmyelinated axons have a tsd exceeding 1 ms (Ranck, 1975; West & Wolstencroft, 1983; Nowak & Bullier, 1998a).”
    BackgroundMethodInfluential
  • Strength-duration properties of human peripheral nerve

    Mogyoros, I., Kiernan, M. C., & Burke, D. (1996) · Brain · doi:10.1093/brain/119.2.439 · Cited by 358 · cited 2×

    “The tsd values of large axons are 3±43 higher when peripheral nerves are stimulated with surface electrodes (Mogyoros et al., 1996), presumably due to the large electrode size (10 mm diameter), the rather large distance from the target ®bres and the electrical impedance of the skin.”
    Background

Show all 2 references

Cited by

See all 128

Metadata

Authors
Holsheimer, J., Demeulemeester, H., Nuttin, B., & de Sutter, P.
Venue
European Journal of Neuroscience
Publisher
Wiley
Published
2000-12
Volume
12
Issue
12
Pages
4573-4577
ISSN
  • 0953-816X (ISSN-L)
  • 1460-9568
OpenAlex
W2091393855
Cited by
128
References
2
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of the target neuronal elements in electrical deep brain stimulation. https://app.cochat.ai/papers/10.1046/j.1460-9568.2000.01306.x
The paper
Holsheimer, J., Demeulemeester, H., Nuttin, B., & de Sutter, P. (2000). Identification of the target neuronal elements in electrical deep brain stimulation. European Journal of Neuroscience. https://doi.org/10.1046/j.1460-9568.2000.01306.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.