CoChat

Frequent and Prolonged Asymptomatic Episodes of Paroxysmal Atrial Fibrillation Revealed by Automatic Long‐Term Event Recorders in Patients with a Negative 24‐Hour Holter

ROCHE, FRÉDÉRIC, GASPOZ, JEAN‐MICHEL, DA COSTA, ANTOINE, ISAAZ, KARL, DUVERNEY, DAVID, PICHOT, VINCENT, COSTES, FRÉDÉRIC, LACOUR, JEAN‐RENÉ, BARTHÉLÉMY, JEAN‐CLAUDE · 2002 · Pacing and Clinical Electrophysiology
Cited by 101

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

ROCHE, F., et al.: Frequent and Prolonged Asymptomatic Episodes of Paroxysmal Atrial Fibrillation Revealed by Automatic Long‐Term Event Recorders in Patients with a Negative 24‐Hour Holter. The presence, frequency, and duration of episodes of paroxysmal atrial fibrillation (PAF) is difficult to establish. This is caused by the limited duration of standard Holter recordings and to the unsatisfactory yield of patient‐triggered event recorders, because of asymptomatic events and of an inconsistent use of the patient dependent triggering function. A prospective cohort of 65 consecutive patients with recurrent palpitations and a negative 24‐hour ECG Holter was investigated by means of a cardiac event recorder bearing continuous automatic arrhythmia analysis and storage. Over a mean duration of 77 ± 36 hours, episodes of PAF were diagnosed in 20 (31%) patients, who had a total of 37 episodes; mean duration of PAF episodes was 7 hours 50 minutes ± 8/hours 45 minutes (minimum 45 minutes, maximum 28 hours). Eleven (55%) of these 20 patients were asymptomatic and would have remained undiagnosed without the automatic mode of the event recorder. Asymptomatic PAF episodes were longer than symptomatic ones (10 hours 30 minutes ± 6 hours 30 minutes vs 4 hours 50 minutes ± 4 hours, P < 0.05). In addition, episodes of sustained paroxysmal supraventricular tachycardia (PSVT) were diagnosed in 39 (57%) patients, of whom 34 (87%) were symptomatic. In this prospective cohort, a second standard 24‐hour monitoring would have missed 44% of the patients with PAF or PSVT and a classical patient‐triggered event recorder 13%. In patients still complaining of palpitations after one negative 24‐hour Holter, numerous, prolonged, and often asymptomatic episodes of PAF can be revealed by long‐term automatic event recorders. These devices should help clarify the clinical consequences of such episodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2002.01587.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 101

Metadata

Authors
ROCHE, F., GASPOZ, J., DA COSTA, A., ISAAZ, K., DUVERNEY, D., PICHOT, V., COSTES, F., LACOUR, J., & BARTHÉLÉMY, J.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2002-11
Volume
25
Issue
11
Pages
1587-1593
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2127270213
Cited by
101
References
8
FWCI
1.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Frequent and Prolonged Asymptomatic Episodes of Paroxysmal Atrial Fibrillation Revealed by Automatic Long‐Term Event Recorders in Patients with a Negative 24‐Hour Holter. https://app.cochat.ai/papers/10.1046/j.1460-9592.2002.01587.x
The paper
ROCHE, F., GASPOZ, J., DA COSTA, A., ISAAZ, K., DUVERNEY, D., PICHOT, V., COSTES, F., LACOUR, J., & BARTHÉLÉMY, J. (2002). Frequent and Prolonged Asymptomatic Episodes of Paroxysmal Atrial Fibrillation Revealed by Automatic Long‐Term Event Recorders in Patients with a Negative 24‐Hour Holter. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2002.01587.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.