Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 217

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Echocardiographic Modeling of Cardiac Dyssynchrony Before and During Multisite Stimulation: A Prospective Study

CAZEAU, S., BORDACHAR, P., JAUVERT, G., LAZARUS, A., ALONSO, C., VANDRELL, M.C., MUGICA, J., RITTER, P. · 2003 · Pacing and Clinical Electrophysiology

Abstract

CAZEAU, S., et al.: Echocardiographic Modeling of Cardiac Dyssynchrony Before and During Multisite Stimulation: A Prospective Study. Multisite biventricular pacing therapy offers significant clinical improvement in some stimulated patients with electrocardiographic criteria of cardiac dyssynchrony. However, observational data increasingly suggest that patients suffering from congestive heart failure in presence of modest QRS widening may also derive benefit from cardiac resynchronization therapy (CRT), and that some patients can be significantly improved clinically after system implantation despite no apparent change in QRS width. This pilot study explored the value of an echocardiographic model to identify cardiac electromechanical dyssynchrony parameters (EDP) in candidates for CRT, and their potential correction after implantation. The study included 66 consecutive CRT recipients of CRT in NYHA functional class III or IV who had one or more atrioventricular, interventricular or intraventricular dyssynchrony criteria. An immediate improvement was observed in 85% of the population with a partial or total correction of their EDP. However, the modifications in EDP differed considerably between recipients of de novo CRT systems and patients with previously implanted standard pacing systems upgraded with the implantation of a left ventricular lead. EDP measurements appear to identify potential candidates for CRT, and to confirm the success of system implantation. (PACE 2003; 26[Pt. II]:137–143)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.00003.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 217

Metadata

Authors
CAZEAU, S., BORDACHAR, P., JAUVERT, G., LAZARUS, A., ALONSO, C., VANDRELL, M. C., MUGICA, J., & RITTER, P.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-01
Volume
26
Issue
1p2
Pages
137-143
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2091884139
Cited by
217
References
1
FWCI
8.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Echocardiographic Modeling of Cardiac Dyssynchrony Before and During Multisite Stimulation: A Prospective Study. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.00003.x
The paper
CAZEAU, S., BORDACHAR, P., JAUVERT, G., LAZARUS, A., ALONSO, C., VANDRELL, M. C., MUGICA, J., & RITTER, P. (2003). Echocardiographic Modeling of Cardiac Dyssynchrony Before and During Multisite Stimulation: A Prospective Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.00003.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.