CoChat

Cardiac Arrhythmias and Risk Stratification After Myocardial Infarction: Results of the CARISMA Pilot Study

HUIKURI, HEIKKI V., MAHAUX, VÉRONIQUE, BLOCH‐THOMSEN, POUL‐ERIK, CARISMA Investigators · 2003 · Pacing and Clinical Electrophysiology
Cited by 55

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

HUIKURI, H.V., et al .: Cardiac Arrhythmias and Risk Stratification After Myocardial Infarction: Results of the CARISMA Pilot Study. CARISMA is a multicenter study enrolling patients with a left ventricular ejection fraction ≤40% after acute myocardial infarction (AMI), in whom an electrocardiogram (ECG) loop recorder (ILR) is implanted to measure the incidence of tachyarrythmia and bradyarrhythmia episodes. The value of 24 hour ambulatory ECG, signal‐averaged ECG late potentials, QT dispersion, T wave alternans, and electrophysiologic testing as predictors of life‐threatening arrhythmias is examined. The study tested the automatic documentation of arrhythmias by the ILR in 30 post‐AMI patients. Results: At a mean follow‐up of 47 days, the ILR had detected atrial tachyarrhythmias in 8 of 28 patients, nonsustained ventricular tachycardias in 2, and transient third degree atrioventricular block in 3. An indication for implantation of an implantable cardioverter defibrillator (ICD) or permanent pacemaker (PM) was observed in 9 out of 29 patients (31%). An average of 2.3 events stored by the ILR were due to inappropriate triggering. Because its memory size is limited to a maximum of 14 episodes, the ILR was unable to store arrhythmias 28% of the follow‐up time. False events rate and monitoring time were improved by suturing the device within its pocket. Conclusions: The ILR allowed the automatic detection of brady‐ and tachyarrhythmias in post‐AMI patients, though a high incidence of false activations were observed. Clinically significant arrhythmias were recorded in a large number of patients with depressed left ventricular function early after AMI. This prompted the implantation of ICD or PM in nearly one third of patients. (PACE 2003; 26[Pt. II]:416–419)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.00061.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 55

Metadata

Authors
HUIKURI, H. V., MAHAUX, V., BLOCH‐THOMSEN, P., & CARISMA Investigators
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-01
Volume
26
Issue
1p2
Pages
416-419
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1841598902
Cited by
55
References
2
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Arrhythmias and Risk Stratification After Myocardial Infarction: Results of the CARISMA Pilot Study. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.00061.x
The paper
HUIKURI, H. V., MAHAUX, V., BLOCH‐THOMSEN, P., & CARISMA Investigators. (2003). Cardiac Arrhythmias and Risk Stratification After Myocardial Infarction: Results of the CARISMA Pilot Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.00061.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.