CoChat

Phantom Validation of Multichannel Magnetocardiography Source Localization

FENICI, RICCARDO, BRISINDA, DONATELLA, NENONEN, JUKKA, FENICI, PETER · 2003 · Pacing and Clinical Electrophysiology
Cited by 25

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

FENICI, R., et al.: Phantom Validation of Multichannel Magnetocardiography Source Localization. Multichannel magnetocardiography (MMCG) is used clinically for noninvasive localization of the site of origin of cardiac arrhythmias. However, its accuracy in unshielded environments is still unknown. The aim of this study was to test the accuracy of three‐dimensional localization of intracardiac sources by means of MMCG in an unshielded catheterization laboratory using a saline‐filled phantom, together with a nonmagnetic catheter designed for multiple monophasic action potential recordings in a clinical setting. A nine‐channel direct current superconducting quantum interference device (DC‐SQUID) system (sensitivity fT/Hz 0.5) was used for MMCG from 36 points in a measuring area of 20 × 20 cm. The artificial sources to be localized were dipoles embedded in the distal end of the catheter, placed 12 cm below the sensor's plane. Equivalent current dipoles, effective magnetic dipoles, and distributed currents models were used for the inverse solution. The localization error was estimated as the three‐dimensional difference between the physical position of the tip of the catheter and the three‐dimensional localization of the dipoles derived by means of the inverse solution calculated from MMCG data. The reproducibility was tested by repeating the MMCG after repositioning the phantom and the measurement system. The average location error of the catheter dipole was 9 ± 4 mm and was due primarily to imprecise depth estimation. Localization was reproducible within 0.73 mm. The distributed currents model provided an accurate image of current distribution centered over the catheter tip. The authors conclude that MMCG estimation is accurate enough to guarantee proper localization of cardiac dipolar sources even in an unshielded clinical electrophysiological laboratory. (PACE 2003; 26[Pt. II]:426–430)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.00063.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 25

Metadata

Authors
FENICI, R., BRISINDA, D., NENONEN, J., & FENICI, P.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-01
Volume
26
Issue
1p2
Pages
426-430
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1971035310
Cited by
25
References
6
FWCI
1.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phantom Validation of Multichannel Magnetocardiography Source Localization. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.00063.x
The paper
FENICI, R., BRISINDA, D., NENONEN, J., & FENICI, P. (2003). Phantom Validation of Multichannel Magnetocardiography Source Localization. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.00063.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.