From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology?
The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.
Abstract
Three-dimensional electroanatomical imaging is increasingly used in interventional cardiac electrophysiology, to guide catheter ablation of cardiac arrhythmias. At the same time, there is a growing interest for non-invasive methods, such as magnetocardiographic mapping (MCG), to localize the arrhythmogenic substrates, to test their reproducibility and to plan the most appropriate interventional approach. So far electroanatomical imaging has relayed on static mathematical modeling of the heart and more recently on direct merging with three-dimensional rendering of cardiac anatomy from multidetector computer tomography or magnetic resonance imaging. Merging electrophysiological information with static anatomical structures, can surely be a source of uncertainty for MCG-based pre-interventional localization of the arrhythmogenic substrate and causes mismatch between the real-time imaging of moving catheters and the static geometry of the cardiac chambers reconstructed with invasive electroanatomical imaging. The implementation of recent realistic numerical models of the beating heart in a breathing thorax can improve accuracy and fill the gap between non-invasive and interventional electroanatomical imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The usefulness of MCG for a better understanding of the arrhythmogenic mechanisms underlying the high-risk J syndromes (225, 327–336); the identification of atrial arrhythmogenic vulnerability (248), of left atrial dysfunction (330), and of the atrial propagation pathways (228); and the dominant frequencies (181, 183, 189, 232) in patients with atrial fibrillation, as well as providing accurate”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [335]
Citations
Cites
Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Bänsch, D., Antz, M., & Kuck, K.-H. (2004) · Circulation · doi:10.1161/01.cir.0000125126.83579.1b · Cited by 353
LocaLisa: New Technique for Real-Time 3-Dimensional Localization of Regular Intracardiac Electrodes
Wittkampf, F. H. M., Wever, E. F. D., Derksen, R., Wilde, A. A. M., Ramanna, H., Hauer, R. N. W., & Robles de Medina, E. O. (1999) · Circulation · doi:10.1161/01.cir.99.10.1312 · Cited by 238
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 2×
“Along the last decade, multiple modeling, simulation, experimental and clinical studies have comparatively assessed the accuracy of MCG and BSPM for non-invasive localization of arrhythmogenic substrates [ 6 ]-[11].”
BackgroundMethodSelf-citationRecent advances in magnetocardiography
Koch, H. C. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.035 · Cited by 108
Part IV Visual determination of generators of the magnetocardiogram
Hosaka, H., & Cohen, D. (1976) · Journal of Electrocardiology · doi:10.1016/s0022-0736(76)80043-x · Cited by 74
YAMADA, S., & YAMAGUCHI, I. (2005) · Internal Medicine · doi:10.2169/internalmedicine.44.1 · Cited by 70
Solving the inverse problem in magnetocardiography
Nenonen, J. T. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.310989 · Cited by 59
GUREVITZ, O. T., GLIKSON, M., ASIRVATHAM, S., KESTER, T. A., GRICE, S. K., MUNGER, T. M., REA, R. F., SHEN, W., JAHANGIR, A., PACKER, D. L., et al. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.09477.x · Cited by 51
Nakai, K., Kawazoe, K., Izumoto, H., Tsuboi, J., Oshima, Y., Oka, T., Yoshioka, K., Shozushima, M., Suwabe, A., Itoh, M., et al. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-005-0652-1 · Cited by 34
Hren, R., Zhang, X., & Stroink, G. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520014 · Cited by 32
Cited by
The dream of near-zero X-rays ablation comes true
Gaïta, F., Guerra, P. G., Battaglia, A., & Anselmino, M. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw223 · Cited by 98
“Pre-acquired electrocardiogram and respiration triggered biplane short sequences of conventional fluoroscopic frames allow traditional catheter and structure visualization tracking within dynamic, virtual cardiac chamber models (4D model).(11)”
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Self-citationCatheter ablation of atrial fibrillation supported by novel nonfluoroscopic 4D navigation technology
Rolf, S., John, S., Gaspar, T., Dinov, B., Kircher, S., Huo, Y., Bollmann, A., Richter, S., Arya, A., Hindricks, G., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.05.008 · Cited by 38
Rolf, S., Sommer, P., Gaspar, T., John, S., Arya, A., Hindricks, G., & Piorkowski, C. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.971705 · Cited by 35
Schoene, K., Rolf, S., Schloma, D., John, S., Arya, A., Dinov, B., Richter, S., Bollmann, A., Hindricks, G., & Sommer, P. (2015) · EP Europace · doi:10.1093/europace/euu398 · Cited by 24
Metadata
- Authors
- Fenici, R., & Brisinda, D.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 1
- Pages
- 5995-5998
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2153066070
- Cited by
- 10
- References
- 25
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2018: 1 · 2016: 1 · 2015: 1 · 2013: 2 · 2012: 1
- FWCI
- 0.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- 4D cardiac imaging, electroanatomical mapping, magnetocardiography, arrhythmia ablation, cardiac electrophysiology, cardiac modeling, catheter ablation planning, non-invasive mapping
- MeSH terms
- Arrhythmias, Cardiac, Humans, Image Interpretation, Computer-Assisted, Intraoperative Care, Catheter Ablation, Body Surface Potential Mapping, Imaging, Three-Dimensional, Surgery, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology? https://app.cochat.ai/papers/10.1109/iembs.2007.4353714
- The paper
- Fenici, R., & Brisinda, D. (2007). From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology? 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4353714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.