CoChat

From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology?

Fenici, R., Brisinda, D. · 2007 · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society

The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.

Abstract

Three-dimensional electroanatomical imaging is increasingly used in interventional cardiac electrophysiology, to guide catheter ablation of cardiac arrhythmias. At the same time, there is a growing interest for non-invasive methods, such as magnetocardiographic mapping (MCG), to localize the arrhythmogenic substrates, to test their reproducibility and to plan the most appropriate interventional approach. So far electroanatomical imaging has relayed on static mathematical modeling of the heart and more recently on direct merging with three-dimensional rendering of cardiac anatomy from multidetector computer tomography or magnetic resonance imaging. Merging electrophysiological information with static anatomical structures, can surely be a source of uncertainty for MCG-based pre-interventional localization of the arrhythmogenic substrate and causes mismatch between the real-time imaging of moving catheters and the static geometry of the cardiac chambers reconstructed with invasive electroanatomical imaging. The implementation of recent realistic numerical models of the beating heart in a breathing thorax can improve accuracy and fill the gap between non-invasive and interventional electroanatomical imaging.

Overview

Integrity signals

Registry

Crossref · 10.1109/iembs.2007.4353714

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

See all 10

Metadata

Authors
Fenici, R., & Brisinda, D.
Affiliations
Università Cattolica del Sacro Cuore (IT)
Venue
2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2007-08
Volume
1
Pages
5995-5998
ISSN
1557-170X (ISSN-L)
OpenAlex
W2153066070
Cited by
10
References
25
Citations by year
2025: 1 · 2023: 1 · 2022: 1 · 2018: 1 · 2016: 1 · 2015: 1 · 2013: 2 · 2012: 1
FWCI
0.00
Type
conference paper
Language
en
Open access
closed
Locations
  • Conference proceedings (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
4D cardiac imaging, electroanatomical mapping, magnetocardiography, arrhythmia ablation, cardiac electrophysiology, cardiac modeling, catheter ablation planning, non-invasive mapping
MeSH terms
Arrhythmias, Cardiac, Humans, Image Interpretation, Computer-Assisted, Intraoperative Care, Catheter Ablation, Body Surface Potential Mapping, Imaging, Three-Dimensional, Surgery, Computer-Assisted

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology? https://app.cochat.ai/papers/10.1109/iembs.2007.4353714
The paper
Fenici, R., & Brisinda, D. (2007). From 3D to 4D imaging: is that useful for interventional cardiac electrophysiology? 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4353714

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.