CoChat

Utility and Safety of Prolonged Temporary Transvenous Pacing Using an Active‐Fixation Lead: Comparison with a Conventional Lead

DE COCK, C.C., VAN CAMPEN, C.M.C., IN'T VELD, J.A., VISSER, C.A. · 2003 · Pacing and Clinical Electrophysiology
Cited by 38

The DOI matches its Crossref record.

Abstract

Transvenous temporary pacing is associated with a substantial dislocation rate reported to range from 10 to 37%. The aim of the study was to assess the safety and utility of a recently introduced 3.5 Fr temporary pacing lead using active fixation in a consecutive series of 36 patients with prolonged (≥48 hours) transvenous temporary pacing (validation group). A group of 36 patients with prolonged transvenous pacing managed with a passive‐fixation lead just prior to the introduction of the active‐fixation lead served as a control group (reference group). Pacing related adverse events included dislocation, inappropriate pacing (i.e., two‐fold or greater increase of initial pacing threshold), local infection, and thrombosis. There were no significant differences in patient characteristics or duration of pacing ( 5.84 ± 2.4 days in the reference group vs 5.94 ± 2.6 days in the validation group). Acute pacing threshold was significantly higher in the validation group as compared to the reference group ( 1.38 ± 0.67 V vs. 0.7 ± 0.21 V, P < 0.01 ). The dislocation rate was significantly lower in the validation group as compared to the reference group (5.5 vs 33.3%, P < 0.001 ). There were 11 (31%) pacing related adverse events in the validation group versus 21 (58%) in the reference group (P < 0.01) . The vast majority of patients in the validation group (75%) had ambulatory temporary pacing. Thus, transvenous temporary pacing using active fixation is safe and is associated with a low dislocation rate and a reduction in pacing related adverse events. (PACE 2003; 26:1245–1248)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2003.t01-1-00175.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. 10.1016/0002-8703(73)90178-6 · DOI
  2. Hynes JK, 1983, Five‐year experience with temporary pacemaker therapy in the coronary care unit, Mayo Clin Proc, 58, 122
  3. 10.1016/0002-9149(82)90505-7 · DOI
  4. Winner S, 1989, Clinical problems with temporary pacemakers prior to permanent pacing, J R Coll Physicians Lond, 23, 161
  5. Andrews R, 1992, Temporary pacing: Continuing failures in medical management, Br Heart J, 68, 91
  6. 10.1136/bmj.312.7039.1134 · DOI · Paper page
  7. 10.1016/0002-8703(63)90330-2 · DOI
  8. 10.1136/heart.83.6.715 · doi:10.1136/heart.83.6.715
  9. Mond HG, 1992, The electrodes‐tissue interface: The revolutionary role of steroid elution, PACE, 15, 95, 10.1111/j.1540-8159.1992.tb02905.x · DOI · Paper page
  10. 10.1136/bmj.323.7312.527 · doi:10.1136/bmj.323.7312.527
  11. 10.1136/pgmj.75.888.577 · doi:10.1136/pgmj.75.888.577

Cited by

See all 38

Metadata

Authors
DE COCK, C. C., VAN CAMPEN, C. M. C., IN'T VELD, J. A., & VISSER, C. A.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2003-04-24
Volume
26
Issue
5
Pages
1245-1248
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2032022084
Cited by
38
References
0
FWCI
0.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Utility and Safety of Prolonged Temporary Transvenous Pacing Using an Active‐Fixation Lead: Comparison with a Conventional Lead. https://app.cochat.ai/papers/10.1046/j.1460-9592.2003.t01-1-00175.x
The paper
DE COCK, C. C., VAN CAMPEN, C. M. C., IN'T VELD, J. A., & VISSER, C. A. (2003). Utility and Safety of Prolonged Temporary Transvenous Pacing Using an Active‐Fixation Lead: Comparison with a Conventional Lead. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2003.t01-1-00175.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.