Assessment of blood pressure in patients with Type 2 diabetes: comparison between home blood pressure monitoring, clinic blood pressure measurement and 24‐h ambulatory blood pressure monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aims To compare a home blood pressure (BP) monitoring device and clinic BP measurement with 24‐h ambulatory BP monitoring in patients with Type 2 diabetes mellitus (DM). Methods Fifty‐five patients with type 2 DM had BP measured at three consecutive visits to the DM clinic by nurses using a stethoscope and mercury sphygmomanometer (CBP). Twenty‐four‐hour ambulatory BP was measured using a Spacelabs 90207 automatic cuff‐oscillometric device (ABPM). Subjects were then instructed in how to use a Boots HEM 732B semiautomatic cuff‐oscillometric home BP monitoring device and measured BP at home on three specified occasions on each of 4 consecutive days at varying times (HBPM). Results Correlations between HBPM and ABPM were r = 0.88, P < 0.001 for systolic BP and r = 0.76, P < 0.001 for diastolic BP, with correlations between CBP and ABPM being systolic r = 0.59, P < 0.001, diastolic r = 0.47, P < 0.001. HBPM agreed with ABPM more closely compared with CBP (CBP +10.9/+3.8 (95% confidence intervals (CI) 6.9, 14.8/1.6, 6.1) vs. HBPM +8.2/+3.7 (95% CI 6.0, 10.3/2.0, 5.4)). The sensitivity, specificity and positive predictive value of HBPM in detecting hypertension were 100%, 79% and 90%, respectively, compared with CBP (85%, 46% and 58%, respectively). Conclusions In patients with Type 2 DM, home BP monitoring is superior to clinic BP measurement, when compared with 24‐h ambulatory BP, and allows better detection of hypertension. It would be a rational addition to the annual review process. Diabet. Med. 18, 431–437 (2001)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Home Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Agarwal, R., & Andersen, M. J. (2006) · Kidney International · doi:10.1038/sj.ki.5000081 · Cited by 184
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Metadata
- Authors
- Masding, M. G., Jones, J. R., Bartley, E., & Sandeman, D. D.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 18
- Issue
- 6
- Pages
- 431-437
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2074256589
- Cited by
- 49
- References
- 1
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of blood pressure in patients with Type 2 diabetes: comparison between home blood pressure monitoring, clinic blood pressure measurement and 24‐h ambulatory blood pressure monitoring. https://app.cochat.ai/papers/10.1046/j.1464-5491.2001.00513.x
- The paper
- Masding, M. G., Jones, J. R., Bartley, E., & Sandeman, D. D. (2001). Assessment of blood pressure in patients with Type 2 diabetes: comparison between home blood pressure monitoring, clinic blood pressure measurement and 24‐h ambulatory blood pressure monitoring. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2001.00513.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.