CoChat

The hospital and home use of a 30‐second hand‐held blood ketone meter: guidelines for clinical practice

Wallace, T. M., Meston, N. M., Gardner, S. G., Matthews, D. R. · 2001 · Diabetic Medicine
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Aims To establish the role of the measurement of β‐hydroxybutyrate (β‐OHB) in distinguishing simple hyperglycaemia from ketosis, and as an indicator of adequate resolution of ketoacidosis, using an electrochemical blood ketone meter. The aim of the study is to assess the accuracy and precision of the meter and to develop clinical guidelines for the use of the ketone meter at home and in hospital. Patients and methods Twenty patients with poor glycaemic control (mean HbA 1c 10.2%) were recruited from the diabetes clinic and 14 patients admitted with diabetic ketoacidosis (DKA) were recruited from two Accident and Emergency Departments. The blood obtained at each routine fingerprick test for glucose measurement was tested for β‐OHB using the ketone meter. Plasma β‐OHB concentrations were also measured on admission using a laboratory enzymatic method. Results Paired glucose and β‐OHB meter readings (n = 1099) in clinic patients demonstrated that, in the absence of intercurrent illness, β‐OHB levels did not exceed 1 mmol/l, irrespective of glucose readings. In the 14 ketoacidotic patients, the mean plasma β‐OHB concentration, measured in the laboratory, on admission was 7.4 mmol/l (range 3.9–12.3 mmol/l). The median half‐life of β‐OHB was 1.64 h (1st IQR 2.27 h, 3rd IQR 1.34 h). The median time taken, from the initiation of treatment, for β‐OHB concentrations to fall to below 1 mmol/l was 8.46 h (range 5–58.33 h). Conclusion Near patient blood ketone testing is a useful adjunct to blood glucose monitoring in distinguishing between ketosis and simple hyperglycaemia. The data suggest that β‐OHB levels ≥ 1 mmol/l require further action and levels > 3 mmol/l necessitate medical review. In addition, the rate of fall of β‐OHB in DKA can be used as an indicator of the adequacy of treatment. Diabet. Med. 18, 640–645 (2001)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1464-5491.2001.00550.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Wallace, T. M., Meston, N. M., Gardner, S. G., & Matthews, D. R.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2001-08
Volume
18
Issue
8
Pages
640-645
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2099890668
Cited by
97
References
2
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.