The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy
The DOI matches its Crossref record.
Abstract
Aims To evaluate the introduction of a community‐based non‐mydriatic and mydriatic digital photographic screening programme by measuring the sensitivity and specificity compared with a reference standard and assessing the added value of technician direct ophthalmoscopy. Methods Study patients had one‐field, non‐mydriatic, 45° digital imaging photography prior to mydriatic two‐field digital imaging photography followed by technician ophthalmoscopy. Of these patients, 1549 were then examined by an experienced ophthalmologist using slit lamp biomicroscopy as a reference standard. The setting was general practices in Gloucestershire. Patients were selected by randomizing groups of patients (from within individual general practices) and 3611 patients were included in the study. Patients for reference standard examination were recruited from groups of patients on days when the ophthalmologist was able to attend. The main outcome measure was detection of referable diabetic retinopathy (DR) as defined by the Gloucestershire adaptation of the European Working Party guidelines. Results For mydriatic digital photography, the sensitivity was 87.8%, specificity was 86.1% and technical failure rate was 3.7%. Technician ophthalmoscopy did not alter these figures. For non‐mydriatic photography, the sensitivity was 86.0%, specificity was 76.7% and technical failure rate was 19.7%. Conclusions Two‐field mydriatic digital photography is an effective method of screening for referable diabetic retinopathy. Non‐mydriatic digital photography has an unacceptable technical failure rate and low specificity. Diabet. Med. 20, 467–474 (2003)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The English National Screening Programme for diabetic retinopathy 2003–2016
Scanlon, P. H. (2017) · Acta Diabetologica · doi:10.1007/s00592-017-0974-1 · Cited by 440
Self-citationLi, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
“In real-world screening settings, rates of poor-quality or ungradable images have been reported to be as high as 20% (34,35).”
BackgroundValidation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
“In a study done by Scanlon et al [24], comparing the sensitivity and specificity of mydriatic and nonmydriatic digital retinal screening, with dilated slit lamp biomicroscopy as the reference standard, it was shown that mydriatic digital photography was an effective method of screening for DR while non-mydriatic fundu…”
BackgroundDeb-Joardar, N., Germain, N., Thuret, G., Manoli, P., Garcin, A.-F., Millot, L., Gavet, Y., Estour, B., & Gain, P. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.051 · Cited by 26
Raman, R., Rani, P. K., Mahajan, S., Paul, P., Gnanamoorthy, P., Krishna, M. S., & Sharma, T. (2007) · Telemedicine and e-Health · doi:10.1089/tmj.2006.0084 · Cited by 22
Metadata
- Authors
- Scanlon, P. H., Malhotra, R., Thomas, G., Foy, C., Kirkpatrick, J. N., Lewis‐Barned, N., Harney, B., & Aldington, S. J.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2003-06
- Volume
- 20
- Issue
- 6
- Pages
- 467-474
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2170869778
- Cited by
- 140
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy. https://app.cochat.ai/papers/10.1046/j.1464-5491.2003.00954.x
- The paper
- Scanlon, P. H., Malhotra, R., Thomas, G., Foy, C., Kirkpatrick, J. N., Lewis‐Barned, N., Harney, B., & Aldington, S. J. (2003). The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2003.00954.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.