CoChat

Continuous glucose monitoring for treatment adjustment in diabetic pregnancies—a pilot study

Yogev, Y., Ben‐Haroush, A., Chen, R., Kaplan, B., Phillip, M., Hod, M. · 2003 · Diabetic Medicine
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Aims To examine the efficacy of a continuous glucose monitoring (CGM) system for treatment adjustment in patients with diabetic pregnancy treated with insulin. Methods The study sample consisted of eight women with diabetic pregnancy, six with pre‐pregnancy Type 1 diabetes mellitus and two with gestational diabetes (GDM), all being treated with multiple daily insulin injections. Gestational age ranged from 24 to 32 weeks. Data derived from the Continuous Glucose Monitoring System (MiniMed) for 72 h were compared with fingerstick glucose measurements (six to eight times a day), and treatment was adjusted on the basis of the findings. Two to four weeks later, the patients were re‐evaluated with CGM. Results In the first part of the study, an average of 744 ± 33 glucose measurements was recorded for each patient with CGM. The mean total time of hyperglycaemia (glucose level > 7.7 mmol/l) undetected by the fingerstick method was 152 ± 33 min/day. Nocturnal hypoglycaemic events (glucose level < 2.7 mmol/l) were recorded in seven patients. Based on the additional information obtained by continuous monitoring, the insulin regimen was changed in all patients. CGM re‐evaluation after treatment adjustment showed a reduction in undetected hyperglycaemia to 89 ± 17 min/day and in nocturnal hypoglycaemic events, which were recorded in only one patient. Conclusions Continuous glucose monitoring may diagnose high blood glucose levels and nocturnal hypoglycaemic events that are unrecognized by intermittent blood glucose monitoring and could serve as a useful tool for the long‐term management of diabetic pregnancies. A large prospective study is needed to determine the clinical implications of this new monitoring technique. Diabet. Med. 20, 558–562 (2003)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1464-5491.2003.00959.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 70

Metadata

Authors
Yogev, Y., Ben‐Haroush, A., Chen, R., Kaplan, B., Phillip, M., & Hod, M.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2003-06-27
Volume
20
Issue
7
Pages
558-562
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2138700734
Cited by
70
References
3
FWCI
4.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous glucose monitoring for treatment adjustment in diabetic pregnancies—a pilot study. https://app.cochat.ai/papers/10.1046/j.1464-5491.2003.00959.x
The paper
Yogev, Y., Ben‐Haroush, A., Chen, R., Kaplan, B., Phillip, M., & Hod, M. (2003). Continuous glucose monitoring for treatment adjustment in diabetic pregnancies—a pilot study. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2003.00959.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.