The DOI matches its Crossref record.
A comparative evaluation of digital imaging, retinal photography and optometrist examination in screening for diabetic retinopathy
Abstract
Aims To compare the respective performances of digital retinal imaging, fundus photography and slit‐lamp biomicroscopy performed by trained optometrists, in screening for diabetic retinopathy. To assess the potential contribution of automated digital image analysis to a screening programme. Methods A group of 586 patients recruited from a diabetic clinic underwent three or four mydriatic screening methods for retinal examination. The respective performances of digital imaging (n = 586; graded manually), colour slides (n = 586; graded manually), and slit‐lamp examination by specially trained optometrists (n = 485), were evaluated against a reference standard of slit‐lamp biomicroscopy by ophthalmologists with a special interest in medical retina. The performance of automated grading of the digital images by computer was also assessed. Results Slit‐lamp examination by optometrists for referable diabetic retinopathy achieved a sensitivity of 73% (52–88) and a specificity of 90% (87–93). Using two‐field imaging, manual grading of red‐free digital images achieved a sensitivity of 93% (82–98) and a specificity of 87% (84–90), and for colour slides, a sensitivity of 96% (87–100) and a specificity of 89% (86–91). Almost identical results were achieved for both methods with single macular field imaging. Digital imaging had a lower technical failure rate (4.4% of patients) than colour slide photography (11.9%). Applying an automated grading protocol to the digital images detected any retinopathy, with a sensitivity of 83% (77–89) and a specificity of 71% (66–75) and diabetic macular oedema with a sensitivity of 76% (53–92) and a specificity of 85% (82–88). Conclusions Both manual grading methods produced similar results whether using a one‐ or two‐field protocol. Technical failures rates, and hence need for recall, were lower with digital imaging. One‐field grading of fundus photographs appeared to be as effective as two‐field. The optometrists achieved the lowest sensitivities but reported no technical failures. Automated grading of retinal images can improve efficiency of resource utilization in diabetic retinopathy screening. Diabet. Med. 20, 528–534 (2003)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ting, D. S. W., Cheung, G. C. M., & Wong, T. Y. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12696 · Cited by 1,066
Niemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Automated Identification of Diabetic Retinopathy Stages Using Digital Fundus Images
Nayak, J., Bhat, P. S., Acharya U, R., Lim, C. M., & Kagathi, M. (2008) · Journal of Medical Systems · doi:10.1007/s10916-007-9113-9 · Cited by 272
Screening for Presence or Absence of Diabetic Retinopathy: A Meta-analysis
Bragge, P. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.319 · Cited by 134
Metadata
- Authors
- Olson, J. A., Strachan, F. M., Hipwell, J. H., Goatman, K. A., McHardy, K. C., Forrester, J. V., & Sharp, P. F.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2003-06-27
- Volume
- 20
- Issue
- 7
- Pages
- 528-534
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2037953114
- Cited by
- 164
- References
- 0
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparative evaluation of digital imaging, retinal photography and optometrist examination in screening for diabetic retinopathy. https://app.cochat.ai/papers/10.1046/j.1464-5491.2003.00969.x
- The paper
- Olson, J. A., Strachan, F. M., Hipwell, J. H., Goatman, K. A., McHardy, K. C., Forrester, J. V., & Sharp, P. F. (2003). A comparative evaluation of digital imaging, retinal photography and optometrist examination in screening for diabetic retinopathy. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2003.00969.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.