Comparability of venous and capillary glucose measurements in blood
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aim Diabetes and glucose intolerance are diagnosed by measurement of glucose in blood. Glucose is usually measured as venous plasma or capillary whole blood and diagnostic criteria frequently provide equivalence estimates for these two methods. This study examined the relationship between glucose measured in capillary and venous samples collected at random, fasting and 2 h after oral glucose. Methods Simultaneous measurements of venous plasma and capillary blood glucose were performed on random samples in 609 people, fasting samples in 685 people, and 2 h after oral glucose samples in 463 people. Separate capillary and venous samples were collected each time. A variance component model was used to construct conversion algorithms between venous and capillary results. Results The relationship between venous and capillary glucose values varied, with venous plasma being higher than capillary blood for random and fasting samples but lower for sampling 2 h after oral glucose. Discrepancies were observed between measured capillary blood values and the published WHO capillary blood equivalence values for venous plasma values for all except a fasting venous value of 7.0 mmol/l. For example, for a fasting venous plasma glucose of 6.1 mmol/l the WHO equivalent value is 5.6 mmol/l, while the measured value was 5.2 mmol/l, and for a 2‐h venous plasma glucose of 11.1 mmol/l the WHO value is 11.1 mmol/l, while the measured result was 11.7 mmol/l. Conclusions These results highlight the difficulty in equating glucose levels from one sampling and measuring procedure to another, and raise uncertainties about current published equivalence values which could lead to misclassifications in glucose tolerance status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
Cited by
Ong, K. L., Stafford, L. K., McLaughlin, S. A., Boyko, E. J., Vollset, S. E., Smith, A. E., Dalton, B. E., Duprey, J., Cruz, J. A., Hagins, H., et al. (2023) · The Lancet · doi:10.1016/s0140-6736(23)01301-6 · Cited by 6,146
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Livesey, G., Taylor, R., Hulshof, T., & Howlett, J. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.1.258s · Cited by 439
Mohan, V., Deepa, M., Deepa, R., Shanthirani, C. S., Farooq, S., Ganesan, A., & Datta, M. (2006) · Diabetologia · doi:10.1007/s00125-006-0219-2 · Cited by 353
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Metadata
- Authors
- Colagiuri, S., Sandbæk, A., Carstensen, B., Christensen, J., Glumer, C., Lauritzen, T., & Borch‐Johnsen, K.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2003-10-22
- Volume
- 20
- Issue
- 11
- Pages
- 953-956
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2056038272
- Cited by
- 101
- References
- 1
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparability of venous and capillary glucose measurements in blood. https://app.cochat.ai/papers/10.1046/j.1464-5491.2003.01048.x
- The paper
- Colagiuri, S., Sandbæk, A., Carstensen, B., Christensen, J., Glumer, C., Lauritzen, T., & Borch‐Johnsen, K. (2003). Comparability of venous and capillary glucose measurements in blood. Diabetic Medicine. https://doi.org/10.1046/j.1464-5491.2003.01048.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.