Multicentre comparison of skin hydration in terms of physical‐, physiological‐ and product‐dependent parameters by the capacitive method (Corneometer CM 825)
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Synopsis: A multicentre study for measuring skin hydration with 349 volunteers was carried out in six different laboratories. The purpose of the study was to investigate physical‐, physiological‐ and product‐dependent parameters of three test emulsions (base, base + moisturizer and base + moisturizer + lipids) in a double‐blind study. A comparison between analogous and digital sensor technology of the Corneometer CM825 was examined. Here, a clear relationship between both sensor types could be highlighted. A vital point of the study was the division of the test subjects according to their skin type. To get more objective limits for three different skin types – very dry, dry and normal skin – visual expert evaluation, self‐assessment and hydration measurements were analysed by means of statistical methods. The moisture‐related skin types were determined as follows: very dry skin was characterized with corneometer units below 30, dry skin between 30 and 40 and normal skin higher than 40 a.u. (arbitrary units). The efficacy of the three test emulsions was examined in relation to the mentioned skin types. Analysing the measured data of all test centres, a clear dependency of skin physiology (skin type) and product efficacy became evident. The drier the skin, the higher the increase of hydration. The product performance of the three test emulsions compared to the untreated control resulted in a significant increase of skin hydration in all measuring centres. The evaluation of a product ranking showed a good differentiation between the basic emulsion and the two other products. An increase of efficacy by adding lipids could be observed in four of six centres. The important influence of the skin type of the volunteers on the degree of product performance, as demonstrated in this study, should be especially considered when drawing up guidelines for efficacy testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Littell, R. C. (1996) · Medical Entomology and Zoology · Cited by 10,554
EEMCO guidance for the assessment of stratum corneum hydration: electrical methods
Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO) (1997) · Skin Research and Technology · doi:10.1111/j.1600-0846.1997.tb00174.x · Cited by 493
Handbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 412
Bioengineering of the skin: Water and the stratum corneum
Edwards, D. A. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(95)90005-5 · Cited by 290
EEMCO guidance for the assessment of dry skin (xerosis) and ichthyosis: clinical scoring systems
Serup, J. (1995) · Skin Research and Technology · doi:10.1111/j.1600-0846.1995.tb00029.x · Cited by 179
Bioengineering of the skin : methods and instrumentation
Berardesca, E. (1995) · CRC Press eBooks · Cited by 163
Textbook of Cosmetic Dermatology
(2010) · CRC Press eBooks · doi:10.3109/9781841847641 · Cited by 124
Pierard, G. (1996) · Skin Research and Technology · doi:10.1111/j.1600-0846.1996.tb00047.x · Cited by 80
Impedance methods for studying skin moisturization
Lévêque, J. L., & de Rigal, J. (1983) · Cited by 78
In Vivo Evaluation of the Hydration State of the Skin: Measurements and Methods for Claim Support
Barel, A., Clarys, P., & Gabard, B. (1999) · Springer eBooks · doi:10.1007/978-3-642-59869-2_5 · Cited by 21
Bimczok, R., Ansmann, A., Leneveu-Duchemin, M. C., Motitschke, L., Pohl, L., & Reng, A.-K. (1994) · Journal of the Society of Cosmetic Chemists · Cited by 7
Self-citation
Cited by
Influence of epidermal hydration on the friction of human skin against textiles
Gerhardt, L.-C., Strässle, V, Lenz, A., Spencer, N. D., & Derler, S. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0034 · Cited by 334
Plessis, J. D., Stefaniak, A., Eloff, F., John, S., Agner, T., Chou, T., Nixon, R., Steiner, M., Franken, A., Kudla, I., et al. (2013) · Skin Research and Technology · doi:10.1111/srt.12037 · Cited by 231
Luebberding, S., Krueger, N., & Kerscher, M. (2013) · International Journal of Cosmetic Science · doi:10.1111/ics.12068 · Cited by 221
“The results are displayed in arbitrary units (CM units), indicating very dry skin (< 30 CM units), dry skin (30–40 CM units) and well-hydrated skin (> 40 CM units) [15].”
BackgroundBolke, L., Schlippe, G., Gerß, J., & Voss, W. (2019) · Nutrients · doi:10.3390/nu11102494 · Cited by 198
“For each measurement time, at least three measurements at different locations in the test area on the forearm were performed [17].”
MethodHeinrich, U., Neukam, K., Tronnier, H., Sies, H., & Stahl, W. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.6.1565 · Cited by 191
Self-citation
Metadata
- Authors
- Heinrich, U., Koop, U., Leneveu‐Duchemin, M. ‐., Osterrieder, K., Bielfeldt, S., Chkarnat, C., Degwert, J., Häntschel, D., Jaspers, S., Nissen, H. ‐., Rohr, M., Schneider, G., & Tronnier, H.
- Venue
- International Journal of Cosmetic Science
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 25
- Issue
- 1-2
- Pages
- 45-53
- ISSN
- 0142-5463 (ISSN-L)
- 1468-2494
- OpenAlex
- W1972086614
- Cited by
- 224
- References
- 12
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.