The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
EEMCO guidance for the assessment of stratum corneum hydration: electrical methods
Abstract
Background/aims: The improvement of stratum corneum hydration is one of the most important claims in the cosmetic industry. Methods: Objective assessment of moisturization can be done with devices based on electrical methods provided these instruments are used in an appropriate manner. Results: This paper deals with the biophysical basis behind these techniques and describes the most important variables, pitfalls and drawbacks related to measurements and current instrumentation. Individual‐related and environment‐related variables are also analyzed as well as study designs for predictive or use tests. Conclusions: Practical suggestions for standardization of measurements are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of non-invasive methods and the skin
Guy, R. H. (1996) · Journal of Controlled Release · doi:10.1016/0168-3659(96)01365-x · Cited by 412
Bioengineering of the skin: Water and the stratum corneum
Edwards, D. A. (1995) · Journal of Controlled Release · doi:10.1016/0168-3659(95)90005-5 · Cited by 290
Friction, capacitance and transepidermal water loss (TEWL) in dry atopic and normal skin
LODEN, M., OLSSON, H., AXELL, T., & LINDE, Y. W. (1992) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1992.tb07810.x · Cited by 207
Non-invasive physiological measurements
Escourrou, P. (1988) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1988.95111 · Cited by 101
Hashimoto‐Kumasaka, K., Takahashi, K., & Tagami, H. (1993) · Acta Dermato Venereologica · doi:10.2340/0001555573335339 · Cited by 95
The influence of a single application of different moisturizers on the skin capacitance.
Lodén, M., & Lindberg, M. (1991) · Acta Dermato Venereologica · doi:10.2340/00015555717982 · Cited by 76
Serup, J. V. (1992) · Acta Dermato Venereologica · doi:10.2340/000155551773438 · Cited by 75
Blichmann, C. W., Serup, J. V., & Winther, A. (1989) · PubMed · Cited by 68
Serup, J. V., & Blichmann, C. W. (1987) · Acta Dermato Venereologica · doi:10.2340/0001555567357359 · Cited by 48
Cited by
Natural skin surface pH is on average below 5, which is beneficial for its resident flora
Lambers, H., Piessens, S., Bloem, A., Pronk, H., & Finkel, P. (2006) · International Journal of Cosmetic Science · doi:10.1111/j.1467-2494.2006.00344.x · Cited by 909
EEMCO Guidance for the Assessment of Transepidermal Water Loss in Cosmetic Sciences
Rogiers, V. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056341 · Cited by 525
Chamlin, S. (2002) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(02)00048-8 · Cited by 449
Nikolovski, J., Stamatas, G. N., Kollias, N., & Wiegand, B. C. (2008) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701239 · Cited by 388
Flexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
Metadata
- Authors
- Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO)
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 1997-05
- Volume
- 3
- Issue
- 2
- Pages
- 126-132
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2023777632
- Cited by
- 493
- References
- 13
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEMCO guidance for the assessment of stratum corneum hydration: electrical methods. https://app.cochat.ai/papers/10.1111/j.1600-0846.1997.tb00174.x
- The paper
- Berardesca, E., & European Group for Efficacy Measurements on Cosmetics and Other Topical Products (EEMCO). (1997). EEMCO guidance for the assessment of stratum corneum hydration: electrical methods. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.1997.tb00174.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.