The effect of gestational age and placental location on the prediction of pre‐eclampsia by uterine artery Doppler velocimetry in low‐risk nulliparous women
The DOI matches its Crossref record.
Abstract
Objective: To assess how placental position and gestational age can influence the value of a diastolic notch of the uterine arteries as a screening test for pre‐eclampsia, in a low‐risk population of healthy nulliparous women. Methods: Color Doppler ultrasound was used to examine both uterine arteries in 654 healthy nulliparas at 4‐week intervals between 20 and 32 weeks. The only criterion for an abnormal result was the presence of an early diastolic notch. In each subject the placental position was also recorded. The major end points were pre‐eclampsia and pre‐eclampsia requiring delivery before the 34th week. Results: Ninety‐eight women (15%) had abnormal flow velocity waveforms at their first visit. Twenty‐one out of 654 women developed pre‐eclampsia (3.2%). The sensitivity of the test became lower as gestational age advanced and ranged from 81% at 20 weeks, to 71.4% at 32 weeks. In contrast, the specificity and positive predictive value increased significantly. Eleven out of 12 women who delivered before 34 weeks had abnormal waveforms at the 24th week. In women with a full lateral placenta, the predictive value of the test was extremely low, especially in cases with unilateral notches. Conclusion: Pre‐eclampsia can be more accurately predicted if, along with the presence of a notch, both gestational age and placental position are taken into account. At week 24 the test maintains a high sensitivity (76.1%), but also has an improved specificity (95.1%) and positive predictive value (34%), which allow the clinician to intervene with a potential preventive treatment. Copyright © 2000 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Papageorghiou, A. T., Yu, C. K. H., Bindra, R., Pandis, G., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00572.x · Cited by 537
World Health Organization Systematic Review of Screening Tests for Preeclampsia
Conde-Agudelo, A., Villar, J., & Lindheimer, M. (2004) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000147599.47713.5d · Cited by 326
Meads, C., Cnossen, J., Meher, S., Juarez-Garcia, A., ter Riet, G., Duley, L., Roberts, T., Mol, B., van der Post, J., Leeflang, M., et al. (2008) · Health Technology Assessment · doi:10.3310/hta12060 · Cited by 323
World Health Organization Systematic Review of Screening Tests for Preeclampsia
Cnossen, J. S., Mol, B. W., van Der Post, J. A. M., Bossuyt, P. M. M., & ter Riet, G. (2005) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000162539.68541.c2 · Cited by 249
Hafner, E., Metzenbauer, M., Höfinger, D., Stonek, F., Schuchter, K., Waldhör, T., & Philipp, K. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2641 · Cited by 137
Metadata
- Authors
- Antsaklis, A., Daskalakis, G., Tzortzis, E., & Michalas, S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 16
- Issue
- 7
- Pages
- 635-639
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2027296152
- Cited by
- 59
- References
- 0
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of gestational age and placental location on the prediction of pre‐eclampsia by uterine artery Doppler velocimetry in low‐risk nulliparous women. https://app.cochat.ai/papers/10.1046/j.1469-0705.2000.00288.x
- The paper
- Antsaklis, A., Daskalakis, G., Tzortzis, E., & Michalas, S. (2000). The effect of gestational age and placental location on the prediction of pre‐eclampsia by uterine artery Doppler velocimetry in low‐risk nulliparous women. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.2000.00288.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.