Nuchal translucency measurement and pregnancy outcome in karyotypically normal fetuses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: The aim of the study was to evaluate the use of nuchal translucency measurement as a marker of adverse pregnancy outcome in karyotypically normal fetuses. Methods: During the years 1995–99, nuchal translucency (NT) measurement was routinely offered to all women who had their dating scan in our unit. From the data collected, we calculated the 95th and 99th centiles of the NT for a given crown–rump length using regression analysis. The NT measurements were analyzed in relation to pregnancy outcome, especially with regards to miscarriage, intrauterine death and diagnosis of fetal structural abnormalities, after excluding chromosomal abnormalities. Results: The pregnancy outcome was available in 6650 (89%) of the 7500 pregnancies. In fetuses with an NT over the 99th centile, 17.8% (relative risk 12.2, 95% CI 7.2–20.8) had an adverse pregnancy outcome (miscarriage, intrauterine death, or termination for fetal abnormality) versus 1.5% for those with a normal measurement. The incidence of structural abnormalities, especially heart defects, was significantly increased in the high‐NT groups. Three out of 11 fetuses with major cardiac abnormalities had an NT measurement over the 99th centile. The calculated relative risk for major heart defects in fetuses with increased NT was 33.5 (95% CI 9–123). Conclusion: In the setting of routine antenatal screening, an increased NT measurement is a marker of a high‐risk pregnancy even in karyotypically normal fetuses. In addition, the increased incidence of structural abnormalities makes the close follow‐up of these pregnancies imperative and should include specialized fetal echocardiography. Copyright © 2001 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Cited by
Increased nuchal translucency with normal karyotype
Souka, A. P., von Kaisenberg, C. S., Hyett, J. A., Sonek, J. D., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.093 · Cited by 517
Challenges in the diagnosis of fetal non‐chromosomal abnormalities at 11–13 weeks
Syngelaki, A., Chelemen, T., Dagklis, T., Allan, L., & Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2642 · Cited by 498
Souka, A. P., Krampl, E., Bakalis, S., Heath, V., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00454.x · Cited by 369
Makrydimas, G., Sotiriadis, A., & Ioannidis, J. P. A. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/s0002-9378(03)00645-8 · Cited by 258
Ghi, T., Huggon, I. C., Zosmer, N., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00584.x · Cited by 167
Metadata
- Authors
- Michailidis, G. D., & Economides, D. L.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2001-02
- Volume
- 17
- Issue
- 2
- Pages
- 102-105
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1997317528
- Cited by
- 154
- References
- 1
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.