Limitations of using first‐trimester nuchal translucency measurement in routine screening for major congenital heart defects
The DOI matches its Crossref record.
Abstract
Objective: To evaluate the effectiveness of nuchal translucency (NT) measurement in screening for major congenital heart disease (CHD) in chromosomally normal fetuses. Design: A population based cohort study of all women having fetal NT measurement at 10–14 weeks of gestation in an unselected population over a 3‐year period. The outcome measure was the identification of major CHD in chromosomally normal pregnancies either antenatally or postnatally. Results: Major defects of the heart and great arteries were identified in 26 out of 7339 pregnancies (prevalence 3.5 per 1000 pregnancies). Out of 26 cases, only four (sensitivity 15.4%, 95% CI 4–35) were in the group of 258 pregnancies (3.5%) with increased NT of ≥ 2.5 mm. The prevalence of major CHD increased from 3.1 per 1000 for NT < 2.5 mm to 50 per 1000 for NT ≥ 3.5 mm (likelihood ratio of 14.1, 95% CI 4.2–47.9). The positive and negative predictive values for NT ≥ 2.5 mm were 1.6% and 99.7%, respectively. Conclusions: The prevalence of major CHD in this study was 3.5 per 1000, suggesting that ascertainment of CHD in our study population was thorough. Fetuses with NT measurements ≥ 3.5 mm have a significantly increased risk of major CHD, and this identifies a subgroup of high‐risk patients in whom early fetal echocardiography would be advocated. The low sensitivity of NT for major CHD in the general population, however, indicates that NT cannot be relied on as the sole or major screening tool for this condition as previously reported. Copyright © 2001 International Society of Ultrasound in Obstetrics and Gynecology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Self-citationIncreased nuchal translucency with normal karyotype
Souka, A. P., von Kaisenberg, C. S., Hyett, J. A., Sonek, J. D., & Nicolaides, K. H. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.12.093 · Cited by 517
Challenges in the diagnosis of fetal non‐chromosomal abnormalities at 11–13 weeks
Syngelaki, A., Chelemen, T., Dagklis, T., Allan, L., & Nicolaides, K. H. (2011) · Prenatal Diagnosis · doi:10.1002/pd.2642 · Cited by 498
Souka, A. P., Krampl, E., Bakalis, S., Heath, V., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2001.00454.x · Cited by 369
Improving the effectiveness of routine prenatal screening for major congenital heart defects
Carvalho, J. S., Mavrides, E., Shinebourne, E. A., Campbell, S., & Thilaganathan, B. (2002) · Heart · doi:10.1136/heart.88.4.387 · Cited by 362
Self-citationMakrydimas, G., Sotiriadis, A., & Ioannidis, J. P. A. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/s0002-9378(03)00645-8 · Cited by 258
(2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2677 · Cited by 256
ISUOG Practice Guidelines (updated): fetal cardiac screening
Carvalho, J. S., Axt‐Fliedner, R., Chaoui, R., Copel, J. A., Cuneo, B. F., Goff, D., Gordin Kopylov, L., Hecher, K., Lee, W., Moon‐Grady, A. J., et al. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26224 · Cited by 246
Self-citationMakrydimas, G., Sotiriadis, A., Huggon, I. C., Simpson, J., Sharland, G., Carvalho, J. S., Daubeney, P. E., & Ioannidis, J. P. A. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.081 · Cited by 194
“evidence to date has been equivocal,(2-6) and the strength of association and the implications for routine screening for cardiac malformations are debated.(5,7) In a recent meta-analysis that combined data from all pertinent published studies in the field, we showed that using a threshold that corresponds to the 99th…”
BackgroundSelf-citationDetailed screening for fetal anomalies and cardiac defects at the 11–13‐week scan
Becker, R., & Wegner, R. ‐. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2709 · Cited by 194
Ghi, T., Huggon, I. C., Zosmer, N., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00584.x · Cited by 167
Ritchie, K., Bradbury, I., Slattery, J., Wright, D., Iqbal, K., & Penney, G. (2005) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2005.00560.x · Cited by 26
Metadata
- Authors
- Mavrides, E., Cobian‐Sanchez, F., Tekay, A., Moscoso, G., Campbell, S., Thilaganathan, B., & Carvalho, J. S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2001-02
- Volume
- 17
- Issue
- 2
- Pages
- 106-110
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2033212653
- Cited by
- 152
- References
- 0
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.