Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record.

Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor

Open access
D. M., Sherer, M., Miodovnik, K. S., Bradley, O., Langer·2002·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: To test the null hypothesis that no correlation exists between transvaginal digital and the gold standard technique of transabdominal suprapubic ultrasound assessments of fetal head position during labor. A secondary objective was to compare the performance of attending physicians vs. senior residents in depicting fetal head position by transvaginal digital examination in comparison with ultrasound, respectively. Methods: Consecutive patients in active labor at term with normal singleton cephalic‐presenting fetuses were included. All participants had ruptured membranes, cervical dilation ≥4 cm and fetal head at ischial spine station –2 or lower. Transvaginal sterile digital examinations were performed by either senior residents or attending physicians and followed immediately by transverse suprapubic transabdominal ultrasound assessments. Examiners were blinded to each other's findings. Power‐analyses dictated number of subjects required. Statistical analyses included Chi‐square, Cohen's Kappa test and logistic regression analysis. P < 0.05 was considered statistically significant. Results: One hundred and two patients were studied (n = 102). In only 24% of patients (n = 24), transvaginal digital examinations were consistent with ultrasound assessments (P = 0.002, 95% confidence interval, 16–33). Logistic regression revealed that cervical effacement (P = 0.03) and ischial spine station (P = 0.01) significantly affected the accuracy of transvaginal digital examination. Parity, gestational age, combined spinal epidural anesthesia, cervical dilation, birth weight and examiner experience did not significantly affect accuracy of the examination. The accuracy of the transvaginal digital exams was increased to 47% (n = 48) (95% confidence interval, 37–57) when fetal head position at transvaginal digital examination was recorded as correct if reported within ±45° of the ultrasound assessment. The rate of agreement between the two assessment methods for attending physicians vs. residents was 58% vs. 33%, respectively (P = 0.02) with the ±45° analysis. Conclusions: Using ultrasound assessment as the gold standard, our data demonstrate an overall high rate of error (76%) in transvaginal digital determination of fetal head position during active labor, consistent with the null hypothesis. Attending physicians exhibited an almost two‐fold higher success rate in depicting correct fetal head position by physical examination vs. residents in the ±45° analysis. Intrapartum ultrasound increases the accuracy of fetal head position assessment during active labor and may serve as an educational tool for physicians in training. Copyright © 2002 ISUOG

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-0705.2002.00641.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 241

Metadata

Authors
D. M., S., M., M., K. S., B., & O., L.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2002-03
Volume
19
Issue
3
Pages
258-263
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2009103168
Cited by
241
References
0
FWCI
7.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor. https://app.cochat.ai/papers/10.1046/j.1469-0705.2002.00641.x
The paper
D. M., S., M., M., K. S., B., & O., L. (2002). Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.2002.00641.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.