The DOI matches its Crossref record.
Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone
Abstract
We studied articular calcified cartilage (ACC) and the immediately subchondral bone (SCB) in normal and osteoarthritic human femoral heads. Thick slices of human normal reference post mortem (PM) and osteoarthritic (OA) femoral heads (age 55–89 years) were embedded in PMMA, micromilled, carbon coated and studied using quantitative backscattered electron (qBSE) imaging to determine variations in degree of mineralization. With exact microanatomical location, nanoindentation was performed on the same block faces in representative superior (more highly loaded) and medial regions of the joint surface. Using a partial unloading method, elastic modulus as a function of indenter penetration depth was determined using a spherical tipped diamond indenter. A pointed indenter was used to determine the tissue hardness in selected locations. The relationship between mineralization and indentation modulus was more distinct in ACC than in SCB, the latter having a higher matrix concentration with variable collagen orientation. In OA, the bulk of the measurements were coincident with those in the PM samples, although there was a greater range in the levels of mineralization and modulus in ACC. In OA, extremely hypermineralized ACC was found in ACC proper, especially in superior regions, and translocated into SCB and hyaline cartilage. The very highly mineralized cartilage fragments may function as a hard grinding abrasive, accelerating wear rates whether attached to or fragmented from the eburnated surfaces of OA ACC. Highly mineralized regions would also alter loading patterns and thereby contribute to further destruction of the joint tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Polymer Fiber Scaffolds for Bone and Cartilage Tissue Engineering
Zhang, Y., Liu, X., Zeng, L., Zhang, J., Zuo, J., Zou, J., Ding, J., & Chen, X. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201903279 · Cited by 294
Nano-mechanical properties of individual mineralized collagen fibrils from bone tissue
Hang, F., & Barber, A. H. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0413 · Cited by 127
Metadata
- Authors
- Ferguson, V. L., Bushby, A. J., & Boyde, A.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2003-07-23
- Volume
- 203
- Issue
- 2
- Pages
- 191-202
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2100333150
- Cited by
- 236
- References
- 0
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone. https://app.cochat.ai/papers/10.1046/j.1469-7580.2003.00193.x
- The paper
- Ferguson, V. L., Bushby, A. J., & Boyde, A. (2003). Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone. Journal of Anatomy. https://doi.org/10.1046/j.1469-7580.2003.00193.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.