A composite poly‐hydroxybutyrate–glial growth factor conduit for long nerve gap repairs
Open accessThe DOI matches its Crossref record.
Abstract
There is considerable evidence that peripheral nerves have the potential to regenerate in an appropriate microenvironment. We have developed a novel artificial nerve guide composed of poly 3‐hydroxybutyrate (PHB) filled with glial growth factor (GGF) suspended in alginate hydrogel. Gaps of 2–4 cm in rabbit common peroneal nerve were bridged using a PHB conduit containing either GGF in alginate hydrogel (GGF) or alginate alone (Alginate), or with an empty PHB conduit (Empty). Tissues were harvested 21, 42 and 63 days post‐operatively. Schwann cell and axonal regeneration were assessed using quantitative immunohistochemistry. At 21 days, addition of GGF increased significantly the distance of axonal and Schwann cells regeneration in comparison with that observed in Alginate and Empty conduits for both gap lengths. The axons bridged the 2‐cm GGF conduits gap by 63 days, with a comparable rate of regeneration seen in 4‐cm conduits. Schwann cells and axonal regeneration quantity was similar for both gap lengths in each group. However, at all time points the quantity of axonal and Schwann cells regeneration in GGF grafts was significantly greater than in both Alginate and Empty conduits, the latter showing better regeneration than Alginate conduits. The results indicate an inhibitory effect of alginate on regeneration, which is partially reversed by the addition of GGF to the conduits. In conclusion, GGF stimulates a progressive and sustainable regeneration increase in long nerve gap conduits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Biomaterials for the Development of Peripheral Nerve Guidance Conduits
Nectow, A. R., Marra, K. G., & Kaplan, D. L. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0240 · Cited by 395
Current applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Metadata
- Authors
- Mohanna, P. ‐., Young, R. C., Wiberg, M., & Terenghi, G.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2003-11-13
- Volume
- 203
- Issue
- 6
- Pages
- 553-565
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2028895530
- Cited by
- 149
- References
- 0
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A composite poly‐hydroxybutyrate–glial growth factor conduit for long nerve gap repairs. https://app.cochat.ai/papers/10.1046/j.1469-7580.2003.00243.x
- The paper
- Mohanna, P. ‐., Young, R. C., Wiberg, M., & Terenghi, G. (2003). A composite poly‐hydroxybutyrate–glial growth factor conduit for long nerve gap repairs. Journal of Anatomy. https://doi.org/10.1046/j.1469-7580.2003.00243.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.