Cited by 105Electrochemical sensors and biosensorsNeuroscience and Neural EngineeringAnalytical Chemistry and Sensors

Continuous Monitoring of Extracellular Glucose Concentrations in the Striatum of Freely Moving Rats with an Implanted Glucose Biosensor

Open access
Lowry, John P., O'Neill, Robert D., Boutelle, Martyn G., Fillenz, Marianne·1998·Journal of Neurochemistry

Abstract

Abstract: We have used a glucose oxidase‐based sensor implanted in the striatum of freely moving rats to determine the concentration of extracellular glucose in two distinct ways. With a modification of the zero net flux method, in which different concentrations of glucose are infused through a dialysis probe glued to the biosensor, we calculated the concentration at which there was no change in glucose current by regression analysis; this gave a concentration of 0.351 ± 0.016 m M. Calculating the concentration from the basal current and the in vitro calibration of the biosensor was not significantly different from this. The basal extracellular glucose concentration determined by either method remained constant over a period of several days. Infusion of 50 µ M veratridine through the adjacent dialysis probe caused a steep decrease in glucose current as soon as the drug reached the brain in contrast to the delayed fall (7.5 min) seen with microdialysis in previous experiments from this laboratory. These results demonstrate that this biosensor provides a direct, real‐time measure of the extracellular concentration of glucose.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1471-4159.1998.70010391.x

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Microdialysis probes consume much more glucose than electrochemical glucose sensors and may therefore underestimate biofouling effects in vivo.

    “microdialysis probes consume significantly more glucose than electrochemical glucose sensors and therefore may underestimate the effects of biofouling in vivo.105”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 21 · Cited by 105

Research works printed but not linked: 1

  1. Morrison P. F., Bungay P. M., Hsiao J. K., Mefford I. N., Dykstra K. H., and Dedrick R. L. (1991) Quantitative microdialysis, in Microdialysis in the Neurosciences (Robinson T. E. and Justice J. B. Jr., eds), pp. 47-80. Elsevier, Amsterdam.

Authors
Lowry, J. P., O'Neill, R. D., Boutelle, M. G., & Fillenz, M.
Affiliations
  • University College Dublin (IE)
  • King's College London (GB)
  • University of Oxford (GB)
Corresponding author
Fillenz, Marianne
Venue
Journal of Neurochemistry
Publisher
Wiley
Published
1998-01
Volume
70
Issue
1
Pages
391-396
ISSN
  • 0022-3042 (ISSN-L)
  • 1471-4159
OpenAlex
W1976989422
Cited by
105
References
21
Citations by year
2026: 1 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 9 · 2012: 4
FWCI
8.78
Type
journal article
Language
en
Open access
Locations
  • Journal of Neurochemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Maynooth University ePrints and eTheses Archive (Maynooth University) (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
extracellular glucose, glucose biosensor, glucose oxidase, striatum, freely moving rats, veratridine, microdialysis, real-time glucose monitoring
MeSH terms
Animals, Corpus Striatum, Extracellular Space, Glucose, Male, Monitoring, Physiologic, Osmolar Concentration, Veratridine, Biosensing Techniques, Rats, Sprague-Dawley, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review