Continuous Monitoring of Extracellular Glucose Concentrations in the Striatum of Freely Moving Rats with an Implanted Glucose Biosensor
Open accessAbstract
Abstract: We have used a glucose oxidase‐based sensor implanted in the striatum of freely moving rats to determine the concentration of extracellular glucose in two distinct ways. With a modification of the zero net flux method, in which different concentrations of glucose are infused through a dialysis probe glued to the biosensor, we calculated the concentration at which there was no change in glucose current by regression analysis; this gave a concentration of 0.351 ± 0.016 m M. Calculating the concentration from the basal current and the in vitro calibration of the biosensor was not significantly different from this. The basal extracellular glucose concentration determined by either method remained constant over a period of several days. Infusion of 50 µ M veratridine through the adjacent dialysis probe caused a steep decrease in glucose current as soon as the drug reached the brain in contrast to the delayed fall (7.5 min) seen with microdialysis in previous experiments from this laboratory. These results demonstrate that this biosensor provides a direct, real‐time measure of the extracellular concentration of glucose.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Microdialysis probes consume much more glucose than electrochemical glucose sensors and may therefore underestimate biofouling effects in vivo.
“microdialysis probes consume significantly more glucose than electrochemical glucose sensors and therefore may underestimate the effects of biofouling in vivo.105”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [105]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 21 · Cited by 105
Research works printed but not linked: 1
- Morrison P. F., Bungay P. M., Hsiao J. K., Mefford I. N., Dykstra K. H., and Dedrick R. L. (1991) Quantitative microdialysis, in Microdialysis in the Neurosciences (Robinson T. E. and Justice J. B. Jr., eds), pp. 47-80. Elsevier, Amsterdam.
- Authors
- Lowry, J. P., O'Neill, R. D., Boutelle, M. G., & Fillenz, M.
- Affiliations
- University College Dublin (IE)
- King's College London (GB)
- University of Oxford (GB)
- Corresponding author
- Fillenz, Marianne
- Venue
- Journal of Neurochemistry
- Publisher
- Wiley
- Published
- 1998-01
- Volume
- 70
- Issue
- 1
- Pages
- 391-396
- ISSN
- 0022-3042 (ISSN-L)
- 1471-4159
- OpenAlex
- W1976989422
- Cited by
- 105
- References
- 21
- Citations by year
- 2026: 1 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 6 · 2014: 4 · 2013: 9 · 2012: 4
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neurochemistry (publishedVersion)
- PubMed (publishedVersion)
- Maynooth University ePrints and eTheses Archive (Maynooth University) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Keywords
- extracellular glucose, glucose biosensor, glucose oxidase, striatum, freely moving rats, veratridine, microdialysis, real-time glucose monitoring
- MeSH terms
- Animals, Corpus Striatum, Extracellular Space, Glucose, Male, Monitoring, Physiologic, Osmolar Concentration, Veratridine, Biosensing Techniques, Rats, Sprague-Dawley, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review