CoChat

In vivo quantitative near‐infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise

Van Beekvelt, Mireille C. P., Van Engelen, Baziel G. M., Wevers, Ron A., Colier, Willy N. J. M. · 2002 · Clinical Physiology and Functional Imaging
Cited by 146

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The aim of this study was to investigate the performance of in vivo quantitative near‐infrared spectroscopy (NIRS) in skeletal muscle at various workloads. NIRS was used for the quantitative measurement of O 2 consumption (mV˙O 2) in the human flexor digitorum superficialis muscle at rest and during rhythmic isometric handgrip exercise in a broad range of work intensities (10–90% MVC=maximum voluntary contraction force). Six subjects were tested on three separate days. No significant differences were found in mV˙O 2 measured over different days with the exception of the highest workload. The within‐subject variability for each workload measured over the three measurements days ranged from 15·7 to 25·6% and did not increase at the high workloads. The mV˙O 2 was 0·14 ± 0·01 mlO 2 min–1 100 g–1 at rest and increased roughly 19 times to 2·68 ± 0·58 mlO 2 min–1 100 g–1 at 72% MVC. These results show that local muscle oxygen consumption at rest as well as during exercise at a broad range of work intensities can be measured reliably by NIRS, applied to a uniform selected subject population. This is of great importance as direct local measurement of mV˙O 2 during exercise is not possible with the conventional techniques. The method is robust enough to measure over separate days and at various workloads and can therefore contribute to a better understanding of human physiology in both the normal and pathological state of the muscle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1475-097x.2002.00420.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 146

Metadata

Authors
Van Beekvelt, M. C. P., Van Engelen, B. G. M., Wevers, R. A., & Colier, W. N. J. M.
Venue
Clinical Physiology and Functional Imaging
Publisher
Wiley
Published
2002-05
Volume
22
Issue
3
Pages
210-217
ISSN
  • 1475-0961 (ISSN-L)
  • 1475-097X
OpenAlex
W2124042154
Cited by
146
References
3
FWCI
1.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo quantitative near‐infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise. https://app.cochat.ai/papers/10.1046/j.1475-097x.2002.00420.x
The paper
Van Beekvelt, M. C. P., Van Engelen, B. G. M., Wevers, R. A., & Colier, W. N. J. M. (2002). In vivo quantitative near‐infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise. Clinical Physiology and Functional Imaging. https://doi.org/10.1046/j.1475-097x.2002.00420.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.