Hemodialysis vascular access preferences and outcomes in the Dialysis Outcomes and Practice Patterns Study (DOPPS)
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND Synthetic grafts have generally been found to exhibit lower survival rates and higher complication rates than native arteriovenous fistulae. We investigated whether survival of grafts relative to fistulae was better in facilities with a preference for grafts, hypothesizing that such facilities may place more grafts because grafts produced superior outcomes. METHODS The study was based on a national U.S. sample of 133 hemodialysis facilities participating in the Dialysis Outcomes and Practice Patterns Study (DOPPS), a prospective, observational study of dialysis treatment practices and outcomes. Vascular access preferences were ascertained from medical directors, nurse managers, and actual practice within each facility (% graft use among prevalent patients). Logistic regression was used to model the odds ratio (OR) of graft placement (vs. fistula) and Cox regression was used to model time from access creation to initial failure. RESULTS Grafts were preferred by 21% of medical directors and 40% of nurse managers. Patients in facilities in which the medical director or nurse manager expressed a preference for grafts were more than twice as likely to have a graft than a fistula (AOR = 2.3, P < 0.01; reference group = facilities that did not prefer grafts), suggesting that facility preferences influence the type of access created. Overall, grafts were more prevalent than fistulae in dialysis facilities, but displayed a higher relative risk of failure (RR 1.33, P < 0.0001). However, the risk of graft versus fistula failure did not vary by expressed preference of the medical director: the relative risk of graft versus fistula failure was 1.39 in facilities in which the medical director preferred grafts and 1.39 in facilities in which the medical director preferred fistulae. Moreover, the relative risk of graft versus fistula failure was 1.57 in facilities that used more than the median percentage of grafts and 1.19 in facilities that used less than the median percentage of grafts. CONCLUSIONS No evidence was found that graft outcomes are superior in facilities that prefer grafts to fistulae. The observed variation in vascular access practice patterns suggests opportunities for quality improvement if optimal practices can be defined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.10.006 · Cited by 1,080
Vascular access use in Europe and the United States: Results from the DOPPS
Pisoni, R. L., Young, E. W., Dykstra, D. M., Greenwood, R. N., Hecking, E., Gillespie, B., Wolfe, R. A., Goodkin, D. A., & Held, P. J. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00117.x · Cited by 851 · cited 2×
“sample of variation in the use of synthetic bridge grafts versus na133 hemodialysis facilities participating in the Dialysis Out- tive arteriovenous fistulae has been demonstrated within comes and Practice Patterns Study (DOPPS), a prospective, ob- the United States [3] and across several other countries [4].”
BackgroundSelf-citationCanadian Hemodialysis Morbidity Study
Churchill, D. N., Taylor, D. W., Cook, R. J., LaPlante, P., Barre, P., Cartier, P., Fay, W. P., Goldstein, M. B., Jindal, K., Mandin, H., et al. (1992) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(13)80002-9 · Cited by 540
Vascular Access for Hemodialysis Patency Rates and Results of Revision
PALDER, S. B., KIRKMAN, R. L., WHITTEMORE, A. D., HAKIM, R. M., LAZARUS, J. M., & TILNEY, N. L. (1985) · Annals of Surgery · doi:10.1097/00000658-198508000-00015 · Cited by 514 · cited 2×
“[5, 6] and that an important opportunity exists to improve characteristics.”
BackgroundA Survey of Vascular Access for Haemodialysis in The Netherlands
Burger, H., Kootstra, G., de Charro, F., & Letters, P. (1991) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/6.1.5 · Cited by 455
The Dialysis Outcomes and Practice Patterns Study (DOPPS): An international hemodialysis study
Young, E. W., Goodkin, D. A., Mapes, D. L., Port, F. K., Keen, M. L., Chen, K., Maroni, B. L., Wolfe, R. A., & Held, P. J. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.07413.x · Cited by 407 · cited 1×
“METHODS The DOPPS sampling plan and study methods have been described at length elsewher”
MethodSelf-citationHemodialysis vascular access morbidity in the United States
Feldman, H. I., Held, P. J., Hutchinson, J. T., Stoiber, E., Hartigan, M. F., & Berlin, J. A. (1993) · Kidney International · doi:10.1038/ki.1993.153 · Cited by 316 · cited 1×
“dtd" [ ]> Hemodialysis vascular access procedures entail large morbidity and cos”
Self-citationVascular access survival among incident hemodialysis patients in the United States
Woods, J. D., Turenne, M. N., Strawderman, R. L., Young, E. W., Hirth, R. A., Port, F. K., & Held, P. J. (1997) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(97)90564-3 · Cited by 265
Self-citationBay, W. H., Cleef, S. V., & Owens, M. (1998) · American Journal of Nephrology · doi:10.1159/000013380 · Cited by 87 · cited 1×
“Physicians were more likely than nurses to prefer fistulae, in agreement with a prior stud”
Result
Cited by
Tordoir, J., Canaud, B., Haage, P., Konner, K., Basci, A., Fouque, D., Kooman, J., Martin-Malo, A., Pedrini, L., Pizzarelli, F., et al. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm021 · Cited by 645
Ethier, J., Mendelssohn, D. C., Elder, S. J., Hasegawa, T., Akizawa, T., Akiba, T., Canaud, B. J., & Pisoni, R. L. (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn261 · Cited by 566
High rates of death and hospitalization follow bone fracture among hemodialysis patients
Tentori, F., McCullough, K., Kilpatrick, R. D., Bradbury, B. D., Robinson, B. M., Kerr, P. G., & Pisoni, R. L. (2014) · Kidney International · doi:10.1038/ki.2013.279 · Cited by 385
Central Vein Stenosis: A Nephrologist's Perspective
Agarwal, A. K., Patel, B. M., & Haddad, N. J. (2007) · Seminars in Dialysis · doi:10.1111/j.1525-139x.2007.00242.x · Cited by 262
Rayner, H. C., Zepel, L., Fuller, D. S., Morgenstern, H., Karaboyas, A., Culleton, B. F., Mapes, D. L., Lopes, A. A., Gillespie, B. W., Hasegawa, T., et al. (2014) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2014.01.014 · Cited by 229
Self-citation
Metadata
- Authors
- Young, E. W., Dykstra, D. M., Goodkin, D. A., Mapes, D. L., Wolfe, R. A., & Held, P. J.
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2002-06
- Volume
- 61
- Issue
- 6
- Pages
- 2266-2271
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2017049278
- Cited by
- 164
- References
- 9
- FWCI
- 14.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.