The DOI matches its Crossref record.
Single-Pass Carbon Dioxide Versus Multiple-Pass Er:YAG Laser Skin Resurfacing: A Comparison of Postoperative Wound Healing and Side-Effect Rates
Abstract
BACKGROUND: Ablative laser skin resurfacing with carbon dioxide (CO2) and erbium:yttrium-aluminum-garnet (Er:YAG) lasers has been popularized in recent years and their side effects individually reported. No prior study, however, has directly compared the relative healing times and complications rates between the two different systems. OBJECTIVE: To evaluate and compare postoperative wound healing and short- and long-term side effects of single-pass CO2 and multiple-pass, long-pulsed Er:YAG laser skin resurfacing for the treatment of facial photodamage and atrophic scars. METHODS: A retrospective chart review and analysis of sequential clinical photographs were performed in 100 consecutive patients who underwent laser skin resurfacing with single-pass CO2 (Ultrapulse 5000; Coherent, Palo Alto, CA, N=50) or multiple-pass, long-pulsed Er:YAG laser resurfacing (Contour; Sciton, Palo Alto, CA, N=50). All laser procedures were performed by a single operator for the amelioration of facial rhytides or atrophic scars. The rate of re-epithelialization, duration of erythema, and presence of complications were tabulated. RESULTS: The average time to re-epithelialization was 5.5 days with single-pass CO2 and 5.1 days with long-pulsed Er:YAG laser resurfacing. Postoperative erythema was observed in all patients, lasting an average of 4.5 weeks after single-pass CO2 laser treatment and 3.6 weeks after long-pulsed Er:YAG laser treatment. Hyperpigmentation was seen in 46% of the patients treated with single-pass CO2 and 42% of the patients treated with the long-pulsed Er:YAG laser (average duration of 12.7 and 11.4 weeks, respectively). No incidences of hypopigmentation or scarring were observed. CONCLUSION: Skin resurfacing with single-pass CO2 or multiple-pass long-pulsed Er:YAG laser techniques yielded comparable postoperative healing times and complication profiles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lasers in dermatology: Four decades of progress
Tanzi, E. L., Lupton, J. R., & Alster, T. S. (2003) · Journal of the American Academy of Dermatology · doi:10.1067/mjd.2003.582 · Cited by 350
Self-citationSide Effects and Complications of Fractional Laser Photothermolysis: Experience with 961 Treatments
GRABER, E. M., TANZI, E. L., & ALSTER, T. S. (2008) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2007.34062.x · Cited by 276
Self-citationAcne scarring: A review and current treatment modalities
Rivera, A. E. (2008) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2008.05.029 · Cited by 259
Wang, Y., Wang, M., Xiao, S., Pan, P., Li, P., & Huo, J. (2013) · American Journal of Clinical Dermatology · doi:10.1007/s40257-013-0009-9 · Cited by 69
Complications of Ablative and Nonablative Lasers and Light Sources
Tanzi, E. L., & Alster, T. S. (2008) · Complications in Cutaneous Surgery · doi:10.1007/978-0-387-73152-0_13 · Cited by 6
Self-citation
Metadata
- Authors
- Tanzi, E. L., & Alster, T. S.
- Venue
- Dermatologic Surgery
- Published
- 2003-01
- Volume
- 29
- Issue
- 1
- Pages
- 80-84
- ISSN
- 1076-0512 (ISSN-L)
- 1524-4725
- OpenAlex
- W2055296626
- Cited by
- 169
- References
- 0
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-Pass Carbon Dioxide Versus Multiple-Pass Er:YAG Laser Skin Resurfacing: A Comparison of Postoperative Wound Healing and Side-Effect Rates. https://app.cochat.ai/papers/10.1046/j.1524-4725.2003.29012.x
- The paper
- Tanzi, E. L., & Alster, T. S. (2003). Single-Pass Carbon Dioxide Versus Multiple-Pass Er:YAG Laser Skin Resurfacing: A Comparison of Postoperative Wound Healing and Side-Effect Rates. Dermatologic Surgery. https://doi.org/10.1046/j.1524-4725.2003.29012.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.