Clinical Audit of 5 Years Provision of the Odstock Dropped Foot Stimulator
The DOI matches its Crossref record.
Abstract
The Odstock dropped foot stimulator (ODFS) is a foot switch controlled single channel neuromuscular stimulator for correction of dropped foot. Following a randomized controlled trial, the ODFS was recommended for use in the United Kingdom's National Health Service and a clinical service established. The patient performance was assessed by measurement of walking speed over 10 m, physiological cost index (PCI), and by questionnaire. After 4.5 months stroke patients (n = 111) showed a mean increase in walking speed of 27% and reduction in PCI of 31% with stimulation and changes of 14% and 19%, respectively, unassisted. Multiple sclerosis patients (n = 21) gained similar orthotic benefit but no carry over. The principal reason cited for using the equipment was that it reduced the effort of walking. The principal reasons identified for discontinuing were an improvement in mobility, electrode positioning difficulties, and deteriorating mobility. A comprehensive clinical follow‐up service is essential to achieve the maximum continuing benefit from FES based orthosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275
Self-citationA Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
“This stimulator is a single channel stimulator controlled by a simple foot switch placed usually beneath the heel for the correction of dropped foot in the last seven years [5].”
Neuromuscular Electrical Stimulation for Motor Restoration in Hemiplegia
Knutson, J. S., Fu, M. J., Sheffler, L. R., & Chae, J. (2015) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2015.06.002 · Cited by 175
Position-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Metadata
- Authors
- Taylor, P., Burridge, J., Dunkerley, A., Wood, D., Norton, J., Singleton, C., & Swain, I.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 23
- Issue
- 5
- Pages
- 440-442
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2036169728
- Cited by
- 58
- References
- 0
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Audit of 5 Years Provision of the Odstock Dropped Foot Stimulator. https://app.cochat.ai/papers/10.1046/j.1525-1594.1999.06374.x
- The paper
- Taylor, P., Burridge, J., Dunkerley, A., Wood, D., Norton, J., Singleton, C., & Swain, I. (1999). Clinical Audit of 5 Years Provision of the Odstock Dropped Foot Stimulator. Artificial Organs. https://doi.org/10.1046/j.1525-1594.1999.06374.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.