Comparative In Vitro Evaluation of Two Different Preparations of Small Diameter Polyurethane Vascular Grafts
The DOI matches its Crossref record.
Abstract
Polyurethane (PU) frequently has been used to manufacture small diameter vascular grafts due to its good bicompatibility. In this study, sponge PU small diameter vascular grafts were fabricated from Pellethane 2103, as well as a self‐synthesized PU, by utilization of a salt casting technique and by varying the salt/polymer ratios. Two types were made; one of them had a thin solid layer on the outer surface. The inner surface was identical and was coated with gelatin crosslinked by epoxide. Tensile properties, compliance, platelet activation, and endothelial cell attachment were evaluated in vitro. It was found that for the grafts with an outer nonporous coating, compliance could not be estimated from modulus due to anisotropy. The most compliance‐matched grafts were made of self‐synthesized polyurethane with a salt/polymer ratio 4 to 8 or Pellethane with a ratio 6 to 8 without the outer nonporous coating. The former had better elongation. Self‐synthesized PU had lower platelet adhesion as well as more endothelial attachment than Pellethane. Porosity activated platelets strongly and reduced endothelial adhesion unless the surface was modified by the crosslinked gelatin layer. It was concluded that PU synthesized in our lab with a salt/polymer ratio of at least 4 and coated with epoxy crosslinked gelatin was a better substrate for preparation of small diameter vascular grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Polymeric biomaterials for tissue and organ regeneration
Seal, B. (2001) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(01)00035-3 · Cited by 892
Seifalian, A. M., Tiwari, A., Hamilton, G., & Salacinski, H. J. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06841.x · Cited by 225
Kannan, R. Y., Salacinski, H. J., Odlyha, M., Butler, P. E., & Seifalian, A. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.006 · Cited by 187
Macrophage behavior on surface-modified polyurethanes
Jones, J. A., Dadsetan, M., Collier, T. O., Ebert, M., Stokes, K. S., Ward, R. S., Hiltner, P. A., & Anderson, J. M. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856204323046843 · Cited by 70
Biocompatibility of Poly(carbonate urethane)s with Various Degrees of Nanophase Separation
Hsu, S., & Kao, Y. (2005) · Macromolecular Bioscience · doi:10.1002/mabi.200400163 · Cited by 39
Self-citation
Metadata
- Authors
- Hsu, S., Tseng, H., & Wu, M.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2000-02
- Volume
- 24
- Issue
- 2
- Pages
- 119-128
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2074277398
- Cited by
- 40
- References
- 0
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative In Vitro Evaluation of Two Different Preparations of Small Diameter Polyurethane Vascular Grafts. https://app.cochat.ai/papers/10.1046/j.1525-1594.2000.06338.x
- The paper
- Hsu, S., Tseng, H., & Wu, M. (2000). Comparative In Vitro Evaluation of Two Different Preparations of Small Diameter Polyurethane Vascular Grafts. Artificial Organs. https://doi.org/10.1046/j.1525-1594.2000.06338.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.