Optimizing Parameters for Terminating Cortical Afterdischarges with Pulse Stimulation
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: We previously reported that brief pulses of electrical stimulation (BPSs) can terminate afterdischarges (ADs) during cortical stimulation. We investigated conditions under which BPS is more likely to suppress ADs. Methods: We analyzed parameters altering BPS effectiveness on 200 ADs in seven patients with implanted subdural electrodes. Results: The odds of BPSs stopping ADs was 8.6 times greater at primary sites (directly stimulated electrodes) than at secondary sites (adjacent electrodes) (p = 0.016). BPS applied within 4.5 s after onset of AD had 2 times greater odds of stopping ADs (p = 0.014). BPS applied when AD voltage was negative was 1.9 times more likely to stop ADs (p = 0.012). ADs with rhythmic pattern responded best (p < 0.0001). BPS stopped 100% of ADs not starting immediately after localization stimulus (LS) versus 29% of those starting immediately (p < 0.0001). Conclusions: BPS is more likely to terminate ADs at primary electrodes, if given early, if applied to the negative peak of the AD waveform, if AD has a rhythmic pattern, and if AD did not start immediately after LS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ben‐Menachem, E., Mañon‐Espaillat, R., Ristanovic, R., Wilder, B. J., Stefan, H., Mirza, W., Tarver, W. B., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02482.x · Cited by 683
Locus Coeruleus Lesions Suppress the Seizure‐Attenuating Effects of Vagus Nerve Stimulation
Krahl, S. E., Clark, K. B., Smith, D. C., & Browning, R. A. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01155.x · Cited by 555
Modelling multivariate binary data with alternating logistic regressions
CAREY, V., ZEGER, S. L., & DIGGLE, P. (1993) · Biometrika · doi:10.1093/biomet/80.3.517 · Cited by 514 · cited 5×
“We analyzed the data by using alternating logistic regression (ALR) (26).”
MethodInfluentialFisher, R. S., Uematsu, S., Krauss, G. L., Cysyk, B. J., McPherson, R., Lesser, R. P., Gordon, B., Schwerdt, P., & Rise, M. (1992) · Epilepsia · doi:10.1111/j.1528-1157.1992.tb02192.x · Cited by 383
Self-citationRutecki, P. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05843.x · Cited by 342
Anticonvulsant effect of anterior thalamic high frequency electrical stimulation in the rat
Mirski, M. A., Rossell, L. A., Terry, J. B., & Fisher, R. S. (1997) · Epilepsy Research · doi:10.1016/s0920-1211(97)00034-x · Cited by 329
Brief bursts of pulse stimulation terminate afterdischarges caused by cortical stimulation
Lesser, R. P., Kim, S. H., Beyderman, L., Miglioretti, D. L., Webber, W. R. S., Bare, M., Cysyk, B., Krauss, G., & Gordon, B. (1999) · Neurology · doi:10.1212/wnl.53.9.2073 · Cited by 308
Self-citationVelasco, F., Velasco, M., Ogarrio, C., & Fanghanel, G. (1987) · Epilepsia · doi:10.1111/j.1528-1157.1987.tb03668.x · Cited by 279
Nathan, S. S., Sinha, S. R., Gordon, B., Lesser, R. P., & Thakor, N. V. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90006-h · Cited by 267 · cited 1×
“This is most likely due to decreased current density with greater distance from the point of stimulation (39,40).”
BackgroundSelf-citationVagus Nerve Stimulation for Treatment of Partial Seizures: 2. Safety, Side Effects, and Tolerability
Ramsay, R. E., Uthman, B. M., Augustinsson, L. E., Upton, A. R. M., Naritoku, D., Willis, J., Treig, T., Barolat, G., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02483.x · Cited by 260
Cited by
High-frequency gamma oscillations and human brain mapping with electrocorticography
Crone, N. E., Sinai, A., & Korzeniewska, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59019-3 · Cited by 526
Self-citationClosed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476
Controlling Bursting in Cortical Cultures with Closed-Loop Multi-Electrode Stimulation
Wagenaar, D. A., Madhavan, R., Pine, J., & Potter, S. M. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4209-04.2005 · Cited by 452
Epileptic seizure prediction and control
Iasemidis, L. D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.810705 · Cited by 363
Intractable epilepsy: management and therapeutic alternatives
Schuele, S. U., & Lüders, H. O. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70108-x · Cited by 344
Responsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 309
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E. (2005) · Brain · doi:10.1093/brain/awh491 · Cited by 266
Self-citationJobst, B. C., Kapur, R., Barkley, G. L., Bazil, C. W., Berg, M. J., Bergey, G. K., Boggs, J. G., Cash, S. S., Cole, A. J., Duchowny, M. S., et al. (2017) · Epilepsia · doi:10.1111/epi.13739 · Cited by 245
Brain stimulation for epilepsy: can scheduled or responsive neurostimulation stop seizures?
Morrell, M. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000218233.60217.84 · Cited by 208
Chkhenkeli, S. A., Šramka, M., Lortkipanidze, G. S., Rakviashvili, T. N., Bregvadze, E. S., Magalashvili, G. E., Gagoshidze, T. S., & Chkhenkeli, I. S. (2004) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2004.01.009 · Cited by 204
Seizure prediction for therapeutic devices: A review
Gadhoumi, K., Lina, J.-M., Mormann, F., & Gotman, J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.06.010 · Cited by 190
Local field potential phase modulates the evoked response to electrical stimulation in visual cortex
Allison-Walker, T., Hagan, M. A., Meikle, S. J., Price, N. S. C., & Wong, Y. T. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada828 · Cited by 3
“There have also been investigations using subdural electrodes, focusing on the use of stimulation to treat seizures [33, 34].”
Metadata
- Authors
- Motamedi, G. K., Lesser, R. P., Miglioretti, D. L., Mizuno‐Matsumoto, Y., Gordon, B., Webber, W. R. S., Jackson, D. C., Sepkuty, J. P., & Crone, N. E.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2002-08
- Volume
- 43
- Issue
- 8
- Pages
- 836-846
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1989189053
- Cited by
- 179
- References
- 32
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.