Frequency of immediate adverse effects associated with therapeutic apheresis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Therapeutic apheresis was found to be reasonably safe in prior studies using instruments that are now largely obsolete. The incidence of adverse effects with current instruments and techniques has not been assessed in a large multicenter study. STUDY DESIGN AND METHODS: A survey was conducted in 1995 using a uniform questionnaire that asked about 32 specific events but excluded transient paresthesia and mild vasovagal events. Eighteen centers returned 3429 responses concerning 125 to 500 therapeutic apheresis procedures per center. RESULTS: Two hundred forty‐two adverse events were reported in 163 procedures (4.75% of all procedures; 6.87% of first‐time procedures and 4.28% of repeat procedures). The numbers (incidence) of selected specific events were transfusion reaction, 56 (51 in plasma exchange [PE] with plasma replacement) (1.6%); citrate‐related nausea and/or vomiting, 41 (1.2%); systolic blood pressure <80 mmHg, 34 (1.0%); vasovagal nausea and/or vomiting, 17 (0.5%); pallor and/or diaphoresis, 16 (0.5%); pulse >120, 14 (0.4%); respiratory distress, 9 (0.3%); tetany or seizure, 9 (0.2%); and chills or rigors, 6 (0.2%). Rates for other specific events were <0.1 percent. Vasovagal phenomena were more frequent in procedures done in neurologic patients than in those done in hematology or oncology patients (p = 0.011) or renal or rheumatic patients (p = 0.038). Procedure‐specific rates were red cell exchange, 8 (10.26%) of 78; PE (plasma), 89 (7.81%) of 1140; PE (no plasma), 42 (3.35%) of 1255; leukapheresis, 4 (5.71%) of 70; plateletpheresis, 0 of 18; and autologous peripheral blood progenitor cell collection, 11 (1.66%) of 664. Three deaths were reported; all were attributed to primary disease. CONCLUSION: Therapeutic apheresis procedures are relatively safe, with a 4.75‐percent overall incidence of mostly reversible adverse effects. Among the most commonly performed procedures, the risk is higher for blood component exchanges, especially if allogeneic red cell or plasma transfusion occurs, and lower for peripheral blood progenitor cell collection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complications of plasma exchange
Sutton, D. M. C., Nair, R. C., Rock, G., & Canadian Apheresis Study Group (1989) · Transfusion · doi:10.1046/j.1537-2995.1989.29289146829.x · Cited by 195
Apheresis: Principles and Practice
Marshall, B. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/110.3.406 · Cited by 146
Frequency of immediate adverse effects associated with apheresis donation
McLeod, B. C., Price, T. H., Owen, H., Ciavarella, D., Sniecinski, I., Randels, M. J., & Smith, J. W. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.381098440858.x · Cited by 136
Self-citationComplications of Plasma Exchange in Neurological Patients
Rodnitzky, R. L., & Goeken, J. A. (1982) · Archives of Neurology · doi:10.1001/archneur.1982.00510180028007 · Cited by 81
The Complications of Therapeutic Plasma Exchange
Ziselman, E. M., Bongiovanni, M. B., & Wurzel, H. A. (1984) · Vox Sanguinis · doi:10.1111/j.1423-0410.1984.tb00086.x · Cited by 50
Calcium homeostasis during therapeutic plasma exchange
Silberstein, L. E., Naryshkin, S., Haddad, J. J., & Strauss, J. F. (1986) · Transfusion · doi:10.1046/j.1537-2995.1986.26286152904.x · Cited by 43
Risks and safety practices in hemapheresis procedures.
Dw, H. (1989) · PubMed · Cited by 40
The national survey of plasma exchange and therapeutic cytapheresis in France
Korach, J. M., BUSSEL, A., & Gajdos, P. (1995) · Transfusion Science · doi:10.1016/0955-3886(95)00039-9 · Cited by 25
Adverse Effects Secondary to the Treatment with Plasma Exchange
Puig, L., Mazzara, R., Torras, A., & Castillo, R. (1985) · The International Journal of Artificial Organs · doi:10.1177/039139888500800309 · Cited by 23
Cited by
Complications of therapeutic plasma exchange: A prospective study of 1,727 procedures
Shemin, D., Briggs, D., & Greenan, M. (2007) · Journal of Clinical Apheresis · doi:10.1002/jca.20143 · Cited by 240
“8%, and again, these complications were more common with FFP as the replacement fluid [14].”
BackgroundAdverse reactions associated with mobile therapeutic apheresis: analysis of 17,940 procedures.
Kiprov, D. D., Golden, P., Rohe, R., Smith, S., Hofmann, J., & Hunnicutt, J. (2001) · Journal of Clinical Apheresis · doi:10.1002/jca.1024 · Cited by 46
Plasmapheresis in immunologically mediated polyneuropathies.
Kiprov, D. D., & Hofmann, J. C. (2003) · Therapeutic Apheresis and Dialysis · doi:10.1046/j.1526-0968.2003.00028.x · Cited by 13
Metadata
- Authors
- McLeod, B. C., Sniecinski, I., Ciavarella, D., Owen, H., Price, T. H., Randels, M. J., & Smith, J. W.
- Venue
- Transfusion
- Publisher
- Wiley
- Published
- 1999-03
- Volume
- 39
- Issue
- 3
- Pages
- 282-288
- ISSN
- 0041-1132 (ISSN-L)
- 1537-2995
- OpenAlex
- W2074922136
- Cited by
- 175
- References
- 9
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.