Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Hemovigilance network in France: organization and analysis of immediate transfusion incident reports from 1994 to 1998

Open access
Andreu, Georges, Morel, Pascal, Forestier, François, Debeir, Joëlle, Rebibo, Danielle, Janvier, Gérard, Hervé, Patrick · 2002 · Transfusion

Abstract

BACKGROUND : Hemovigilance networks have been introduced in several countries to improve knowledge of blood transfusion‐related morbidity and mortality. The general organization of the French network and its results from 1994 through March 1999 are presented here. STUDY DESIGN AND METHODS : The hemovigilance network relies on blood transfusion centers and hospital correspondents, who analyze unexpected and untoward blood transfusion‐related effects and transmit a Transfusion Incident Report (TIR) to a national database (Transfusion Incident Reports Electronic Data Management [GIFIT]). RESULTS : As of March 1, 1999, the GIFIT database contained 24,234 TIRs related to incidents that occurred from the start of the hemovigilance network until December 31, 1998. The network was not fully implemented until 1996; but the reporting rate seems to have since stabilized at approximately 7000 per year (2.5 reports per 1000 blood components). The highest reporting rate is observed with platelet concentrates (4.02/1000), followed by RBCs (1.71/1000) and FFP (0.34/1000). Bacterial contamination quickly appeared as a major cause of morbidity and mortality (185 cases and 18 fatalities). However, a general trend of reduction in this type of incident was observed over time, which can be attributed to adoption of several preventive measures. In contrast, major ABO mismatchings during RBC transfusion remained at a constant rate throughout this period and accounted for six fatalities. After the implementation of universal WBC reduction, some incidents known to be related to WBCs, such as nonhemolytic febrile transfusion reactions (NHFTR) and HLA immunization, were dramatically reduced. CONCLUSION : Hemovigilance is an important tool not only to analyze blood transfusion incidents, but also to measure the effects of new processes or corrective actions at a national level.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1537-2995.2002.00202.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 277

Metadata

Authors
Andreu, G., Morel, P., Forestier, F., Debeir, J., Rebibo, D., Janvier, G., & Hervé, P.
Venue
Transfusion
Publisher
Wiley
Published
2002-10
Volume
42
Issue
10
Pages
1356-1364
ISSN
  • 0041-1132 (ISSN-L)
  • 1537-2995
OpenAlex
W2118095436
Cited by
277
References
5
FWCI
13.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemovigilance network in France: organization and analysis of immediate transfusion incident reports from 1994 to 1998. https://app.cochat.ai/papers/10.1046/j.1537-2995.2002.00202.x
The paper
Andreu, G., Morel, P., Forestier, F., Debeir, J., Rebibo, D., Janvier, G., & Hervé, P. (2002). Hemovigilance network in France: organization and analysis of immediate transfusion incident reports from 1994 to 1998. Transfusion. https://doi.org/10.1046/j.1537-2995.2002.00202.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.