Effect of Verapamil on Immediate Recurrence of Atrial Fibrillation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Immediate Recurrence of AF. Introduction: The purpose of this study was to assess the effect of verapamil on immediate recurrences of atrial fibrillation occurring after successful electrical cardioversion. Methods and Results: The effect of verapamil on the recurrence of atrial fibrillation within 5 minutes after successful transthoracic cardioversion was assessed in 19 (5%) of 364 patients undergoing electrical cardioversion. The mean duration of atrial fibrillation was 4.44 ± 3.0 months. In the 19 patients, cardioversion was successful after each of three consecutive cardioversion attempts per patient; however, atrial fibrillation recurred 0.4 ± 0.3 minutes after cardioversion. Verapamil 10 mg was administered intravenously and fourth cardioversion was performed. Cardioversion after verapamil was successful in each patient, and atrial fibrillation did not recur in 9 (47%) of 19 patients (P < 0.001 vs before verapamil). In the remaining 10 patients in whom atrial fibrillation recurred, the duration of sinus rhythm was significantly longer compared with before verapamil (3,6 ± 2.4 min, P < 0.001). The density of atrial ectopy occurring after cardioversion was significantly less after verapamil (21 ± 14 ectopic beats per min) compared with before verapamil (123 ± 52 ectopic beats per min, P < 0.001). Conclusion: Among patients with immediate recurrence of atrial fibrillation after electrical cardioversion, acute calcium channel blockade by verapamil reduces recurrence of atrial fibrillation and extends the duration of sinus rhythm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 467
Burashnikov, A., & Antzelevitch, C. (2003) · Circulation · doi:10.1161/01.cir.0000065578.00869.7c · Cited by 310
Nergardh, A. K., Rosenqvist, M., Nordlander, R., & Frick, M. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl544 · Cited by 65
Metadata
- Authors
- DAOUD, E. G., HUMMEL, J. D., AUGOSTINI, R., WILLIAMS, S., & KALBFLEISCH, S. J.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 11
- Issue
- 11
- Pages
- 1231-1237
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2027866484
- Cited by
- 53
- References
- 1
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.