The DOI matches its Crossref record.
Acquired Pulmonary Vein Stenosis after Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation
Open accessAbstract
PV Stenosis after AF Ablation. Introduction: Elimination of the initiating focus within the pulmonary vein (PV) using radiofrequency (RF) catheter ablation is a new treatment modality for treatment of drug‐refractory atrial fibrillation. However, information on the long‐term safety of RF ablation within the PV is limited. Methods and Results: In 102 patients with drug‐refractory atrial fibrillation and at least one initiating focus from the PV, series transesophageal echocardiography was performed to monitor the effect of RF ablation on the PV. There were 66 foci in the right upper PV and 65 foci in the left upper PV. Within 3 days of ablation, 26 of the ablated right upper PVs (39%) had increased peak Doppler flow velocity (mean 130 ± 28 cm/sec, range 106 to 220), and 15 of the ablated left upper PVs (23%) had increased peak Doppler flow velocity (mean 140 ± 39 cm/sec, range 105 to 219). Seven patients had increased peak Doppler flow velocity in both upper PVs. No factor (including age, sex, site of ablation, number of RF pulses, pulse duration, and temperature) could predict PV stenosis after RF ablation. Three patients with stenosis of both upper PVs experienced mild dyspnea on exertion, but only one had mild increase of pulmonary pressure. There was no significant change of peak and mean flow velocity and of PV diameter in sequential follow‐up studies up to 16 (209 ± 94 days) months. Conclusion: Focal PV stenosis is observed frequently after RF catheter ablation applied within the vein, but usually is without clinical significance. However, ablation within multiple PVs might cause pulmonary hypertension and should be considered a limiting factor in this procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Stabile, G., Bertaglia, E., Senatore, G., De Simone, A., Zoppo, F., Donnici, G., Turco, P., Pascotto, P., Fazzari, M., & Vitale, D. F. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi583 · Cited by 503
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationKarch, M. R., Zrenner, B., Deisenhofer, I., Schreieck, J., Ndrepepa, G., Dong, J., Lamprecht, K., Barthel, P., Luciani, E., Schömig, A., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.491530 · Cited by 381
Metadata
- Authors
- YU, W., HSU, T., TAI, C., TSAI, C., HSIEH, M., LIN, W., LIN, Y., TSAO, H., DING, Y., CHANG, M., & CHEN, S.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 12
- Issue
- 8
- Pages
- 887-892
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1992556932
- Cited by
- 185
- References
- 0
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acquired Pulmonary Vein Stenosis after Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation. https://app.cochat.ai/papers/10.1046/j.1540-8167.2001.00887.x
- The paper
- YU, W., HSU, T., TAI, C., TSAI, C., HSIEH, M., LIN, W., LIN, Y., TSAO, H., DING, Y., CHANG, M., & CHEN, S. (2001). Acquired Pulmonary Vein Stenosis after Radiofrequency Catheter Ablation of Paroxysmal Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2001.00887.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.