The DOI matches its Crossref record.
Clinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers
Abstract
Ablation of Focal Atrial Fibrillation. Introduction: Ablative therapy for atrial fibrillation (AF) by targeting initiating triggers, usually in or around the pulmonary veins, has been reported by several centers. Evidence for an overall improvement in quality of life (QOL) and amelioration of symptoms is lacking. Methods and Results: Seventy‐one patients undergoing attempted ablation of focal AF were followed for 60 ± 33 weeks. QOL and symptom questionnaires were completed 1 month before and 6 months after electrophysiologic study. Twenty‐three patients (32%) underwent electrophysiologic mapping but no ablation because of either insufficient or multifocal ectopy; the other 48 patients (68%) underwent attempted ablation. Sixteen of 48 patients (33%) undergoing ablation, or 16 (23%) of 71 on an intention to‐treat basis, were found at last follow‐up to have persistent sinus rhythm without antiarrhythmic drugs. Patients who underwent mapping without ablation reported no improvements in any QOL or symptom score, whereas patients who had long‐term successful ablation had significant improvements in all six QOL measures. Interestingly, patients who developed AF recurrence after ablation still reported significant improvements in 4 of 6 QOL measures. Four of 48 patients (8.3%) undergoing ablation developed pulmonary vein stenosis. Conclusion: Paroxysmal AF can be treated successfully in some patients by ablating initiating triggers in the pulmonary veins; however, in our experience the recurrence rate (32/48 [68%]) and risk of pulmonary vein stenosis (8%) after ablation are high. Patients with recurrent AF after ablation of focal AF triggers have significant improvement in QOL and symptoms compared with before ablation. Patients and their physicians should carefully balance the risks and benefits before considering ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Packer, D., & Skanes, A. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,305
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Quality of life in patients with atrial fibrillation: a systematic review
Thrall, G., Lane, D., Carroll, D., & Lip, G. Y. H. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.10.057 · Cited by 697
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Metadata
- Authors
- GERSTENFELD, E. P., GUERRA, P., SPARKS, P. B., HATTORI, K., & LESH, M. D.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 12
- Issue
- 8
- Pages
- 900-908
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2007074549
- Cited by
- 191
- References
- 0
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers. https://app.cochat.ai/papers/10.1046/j.1540-8167.2001.00900.x
- The paper
- GERSTENFELD, E. P., GUERRA, P., SPARKS, P. B., HATTORI, K., & LESH, M. D. (2001). Clinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2001.00900.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.