CoChat

Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet‐Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms

SWERDLOW, CHARLES D., BROWN, MARK L., LURIE, KEITH, ZHANG, JIANXIN, WOOD, NICOLE M., OLSON, WALTER H., GILLBERG, JEFFREY M. · 2002 · Journal of Cardiovascular Electrophysiology
Cited by 107

The DOI matches its Crossref record.

Abstract

Morphology Download. Introduction: Present implantable cardioverter defibrillators (ICDs) have algorithms that discriminate supraventricular tachycardia (SVT) from ventricular tachycardia (VT). One type of algorithm is based on differences in morphology of ventricular electrograms during VT and SVT. Prior SVT‐VT discrimination algorithms have not undergone real‐time evaluation in ambulatory patients until they were incorporated permanently into ICDs. This approach may result in incomplete testing of electrogram morphology algorithms because they are influenced by posture, activity, and electrogram maturation. We downloaded software into implanted ICDs to study a novel algorithm that compares morphologies of baseline and tachycardia electrograms based on differences between corresponding coefficients of their wavelet transforms. This comparison is expressed as a match‐percent score. Methods and Results: In 23 patients, we downloaded the wavelet algorithm into implanted ICDs to assess the temporal and postural stability of baseline electrograms as measured by this algorithm and its accuracy for SVT‐VT discrimination. Median follow‐up was 6 months. Software was downloaded into all ICDs without altering other device functions. With few exceptions, percent template match in baseline rhythm was stable with changes in body position, rest versus walking, isometric exercise, and over time (1 and 3 months). Using the nominal match‐percent threshold of 70%, sensitivity for detection of 38 VTs was 100%. Specificity for rejection of 65 SVTs was 78%. SVTs were rejected for a total of 2.7 hours. Inappropriate detections of SVT as VT were caused by electrogram truncation, myopotential interference with low‐amplitude electrograms, waveform alignment error, and rate‐dependent aberrancy. The first three accounted for 69% of inappropriate detections and could have been prevented by optimal programming. The optimal match‐percent threshold was 60% to 70% based on a receiver‐operator characteristic curve. After shocks, the median time for baseline electrogram morphology to normalize was 85 seconds. Conclusion: The wavelet morphology algorithm has high sensitivity for VT detection. Inappropriate detections of SVT as VT may be reduced by optimal programming. Downloadable software permits evaluation of new algorithms in implanted ICDs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2002.00432.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
SWERDLOW, C. D., BROWN, M. L., LURIE, K., ZHANG, J., WOOD, N. M., OLSON, W. H., & GILLBERG, J. M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2002-05
Volume
13
Issue
5
Pages
432-441
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2057672034
Cited by
107
References
0
FWCI
4.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).