Robustness evaluation of computer-aided clinical trials for medical devices
Open accessThe DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Medical cyber-physical systems, such as the implantable cardioverter defibrillator (ICD), require evaluation of safety and efficacy in the context of a patient population in a clinical trial. Advances in computer modeling and simulation allow for generation of a simulated cohort or virtual cohort which mimics a patient population and can be used as a source of prior information. A major obstacle to acceptance of simulation results as a source of prior information is the lack of a framework for explicitly modeling sources of uncertainty in simulation results and quantifying the effect on trial outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Asymptotic Methods in Statistical Decision Theory
Cam, L. L. (1986) · Springer Series in Statistics · doi:10.1007/978-1-4612-4946-7 · Cited by 1,317
Sensitivity analysis: A review of recent advances
Borgonovo, E., & Plischke, E. (2016) · European Journal of Operational Research · doi:10.1016/j.ejor.2015.06.032 · Cited by 1,167 · cited 1×
“This work builds upon results in Bayesian sensitivity analysis and a review of which can be found in [5][22].”
ResultArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600 · cited 1×
“However, physics-based models are difficult to develop and even when they are available, incur large variability in the simulated endpoints due to the uncertainty in the parameters [10].”
BackgroundUse of historical control data for assessing treatment effects in clinical trials
Viele, K., Berry, S., Neuenschwander, B., Amzal, B., Chen, F., Enas, N., Hobbs, B., Ibrahim, J. G., Kinnersley, N., Lindborg, S., et al. (2014) · Pharmaceutical Statistics · doi:10.1002/pst.1589 · Cited by 512 · cited 1×
“Additionally, work has been presented regarding the incorporation of prior information into the design of a prospective trial in the form of historical trials [16][23].”
MethodThe power prior: theory and applications
Ibrahim, J. G., Chen, M., Gwon, Y., & Chen, F. (2015) · Statistics in Medicine · doi:10.1002/sim.6728 · Cited by 341 · cited 2×
“Additionally, work has been presented regarding the incorporation of prior information into the design of a prospective trial in the form of historical trials [16][23].”
MethodRecalls and Safety Alerts Involving Pacemakers and Implantable Cardioverter-Defibrillator Generators
Maisel, W. H. (2001) · JAMA · doi:10.1001/jama.286.7.793 · Cited by 210 · cited 1×
“Even with a successful trial, medical devices are still subject to recalls and safety alerts [21].”
BackgroundCyber–Physical Modeling of Implantable Cardiac Medical Devices
Jiang, Z., Pajic, M., & Mangharam, R. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161241 · Cited by 172 · cited 1×
“The details of the physiological model and the signals that are generated can be found in [17][18][19].”
BackgroundSelf-citationSWERDLOW, C. D., BROWN, M. L., LURIE, K., ZHANG, J., WOOD, N. M., OLSON, W. H., & GILLBERG, J. M. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.00432.x · Cited by 107 · cited 1×
“The device model for the two different devices is implemented according to the description of the algorithms in [6][7].”
MethodArtificial Pancreas: Model Predictive Control Design from Clinical Experience
Toffanin, C., Messori, M., Di Palma, F., De Nicolao, G., Cobelli, C., & Magni, L. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700607 · Cited by 106 · cited 1×
“Some notable examples of utilizing physiological models as virtual endpoints include [14][8].”
BackgroundGold, M. R., Ahmad, S., Browne, K. F., Berg, K. C., Thackeray, L., & Berger, R. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.10.004 · Cited by 66 · cited 3×
“Simulation of real patient cohort endpoints Recruitment of the real cohort was emulated by utilizing the results reported at the conclusion of RIGHT [13], summarized in Table 1.”
BackgroundMethodInfluential
Research works printed but not linked: 2
- Sensitivity Analysis, in Bayesian, Networks: From, Single to Multiple, and Pa- rameters. 2004. UAI 2004 CHAN & DARWICHE. Technical Report is.
- Boston Scientific Corporation. 2007. The Compass -Technical Guide to Boston Scientific Cardiac Rhythm Management Products. Device Documentation (2007).
Cited by
Creation and application of virtual patient cohorts of heart models
Niederer, S. A., Aboelkassem, Y., Cantwell, C. D., Corrado, C., Coveney, S., Cherry, E. M., Delhaas, T., Fenton, F. H., Panfilov, A. V., Pathmanathan, P., et al. (2020) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2019.0558 · Cited by 103
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
“A related work, [47], uses the same model within a Bayesian statistical framework for integrating the ISCT with a concurrent CT, using methods related to Section 2.3.6, and additionally presents a method for quantifying the robustness of the ISCT to underlying modeling assumptions.”
InfluentialBayesian Statistics for Medical Devices: Progress Since 2010
Campbell, G., Irony, T., Pennello, G. A., & Thompson, L. (2023) · Therapeutic Innovation & Regulatory Science · doi:10.1007/s43441-022-00495-w · Cited by 16
Synthetic biomedical data generation in support of In Silico Clinical Trials
Simalatsar, A. (2023) · Frontiers in Big Data · doi:10.3389/fdata.2023.1085571 · Cited by 12
“In the next paper of this series (Jang et al., 2019), the authors presented a robustness evaluation statistical framework that allows for the evaluation of how the outcome of CTs would change with respect to how many patients with certain types of arrhythmia participated in the studies.”
BackgroundBodner, J., & Kaul, V. (2022) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4053565 · Cited by 7
Metadata
- Authors
- Jang, K. J., Pant, Y. V., Zhang, B., Weimer, J., & Mangharam, R.
- Affiliations
- University of Pennsylvania (US)
- Venue
- Proceedings of the 10th ACM/IEEE International Conference on Cyber-Physical Systems
- Publisher
- ACM
- Published
- 2019-04-16
- Pages
- 163-173
- OpenAlex
- W2921369235
- Cited by
- 6
- References
- 19
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 1 · 2020: 1
- FWCI
- 1.24
- Type
- conference paper
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- ACM/IEEE International Conference on Cyber-Physical Systems (ICCPS) (publishedVersion)
- ScholarlyCommons (University of Pennsylvania) (submittedVersion)
- Scholarly Commons (University of Pennsylvania) (submittedVersion)
- Funders
- NSF (1446664)
- Topics
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Social Sciences › Decision Sciences › Management Science and Operations Research › Simulation Techniques and Applications
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods and Bayesian Inference
- Keywords
- medical devices, cyber-physical systems, implantable cardioverter-defibrillator, virtual cohort, uncertainty quantification, robustness analysis, efficacy and safety evaluation, clinical trial results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robustness evaluation of computer-aided clinical trials for medical devices. https://app.cochat.ai/papers/10.1145/3302509.3311058
- The paper
- Jang, K. J., Pant, Y. V., Zhang, B., Weimer, J., & Mangharam, R. (2019). Robustness evaluation of computer-aided clinical trials for medical devices. Proceedings of the 10th ACM/IEEE International Conference on Cyber-Physical Systems. https://doi.org/10.1145/3302509.3311058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.