CoChat

Impaired Negative Chronotropic Response to Adenosine in Patients with Inappropriate Sinus Tachycardia

STILL, AINO‐MAIJA, HUIKURI, HEIKKI V., AIRAKSINEN, K.E. JUHANI, KOISTINEN, M. JUHANI, KETTUNEN, RAIMO, HARTIKAINEN, JUHA, MITRANI, RAUL D., CASTELLANOS, AGUSTIN, MYERBURG, ROBERT J., RAATIKAINEN, M.J. PEKKA · 2002 · Journal of Cardiovascular Electrophysiology
Cited by 31

The DOI matches its Crossref record.

Abstract

Adenosine and Inappropriate Sinus Tachycardia. Introduction: Adenosine is an endogenous nucleoside that has an important role in the diagnosis and treatment of several cardiac arrhythmias. However, its effects on inappropriate sinus tachycardia (IST) are not well established. Methods and Results: In this study, the response to intravenous adenosine (0.1 to 0.15 mg/kg) was studied in 18 patients (age 46 ± 15 years) with IST. In a subset of patients (n = 5), the direct effects of adenosine were assessed during pharmacologic beta‐adrenergic and cholinergic blockade. Atrial cycle length (ACL) was measured before adenosine injection, at the time of the greatest cycle length prolongation, and during the maximum rebound acceleration of heart rate. Eighteen subjects (age 46 ± 11 years) with normal sinus rhythm undergoing clinically indicated electrophysiologic study served as controls. Adenosine did not terminate IST in any patient. The maximum dose of adenosine prolonged the sinus interval significantly, from 780 ± 128 msec to 985 ± 225 msec (P < 0.001) in the control subjects. In contrast, adenosine caused no significant lengthening of atrial cycle length (527 ± 69 msec vs 590 ± 148 msec; P = NS) in the patients with IST. Similar difference in the response to adenosine was seen during the pharmacologic autonomic blockade. The reflex increase of the sinus rate (rebound effect) was greater in the control subjects than in the patients with IST (21.2% ± 9.7% vs 8.5% ± 8.8%; P < 0.001). Conclusion: The usual negative chronotropic effect of adenosine was impaired in the patients with IST. This may have important diagnostic implications and provide new insight into the mechanism(s) of IST.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2002.00557.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
STILL, A., HUIKURI, H. V., AIRAKSINEN, K. E. J., KOISTINEN, M. J., KETTUNEN, R., HARTIKAINEN, J., MITRANI, R. D., CASTELLANOS, A., MYERBURG, R. J., & RAATIKAINEN, M. J. P.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2002-06
Volume
13
Issue
6
Pages
557-562
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1996977553
Cited by
31
References
0
FWCI
0.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.