CoChat

Linearly Scaled, Rate‐Invariant Normal Limits for QT Interval: Eight Decades of Incorrect Application of Power Functions

RAUTAHARJU, PENTTI M., ZHANG, ZHU‐MING · 2002 · Journal of Cardiovascular Electrophysiology
Cited by 117

The DOI matches its Crossref record.

Abstract

Rate‐Invariant Normal Limits for QT Interval. Introduction: Normal limits for QT traditionally are derived as mean ± 2*SD, with rate adjustment done by dividing QT values by power functions such as RR 1/2 (proportional scaling). Methods and Results: We evaluated procedures for deriving normal limits by comparing adjusted QT distributions versus heart rate using ECG data of 11,739 normal men and women aged ≥ 40 years. QT decreased as predicted by many power functions with heart rate but its SD remained relatively unchanged. Consequently, proportional scaling induced rate‐dependent distortion of normal limits. Furthermore, QT distributions by heart rate were variably skewed and non‐normal. Therefore, normal limits expressed as mean ± 2*SD were misleading. Omission of regression intercept was an additional reason for failure of Bazett's and Fridericia's formulas. Regularized normal limits for adjusted QT (Qta) were obtained with linear instead of proportional scaling of type QTa = QT + k1*(1 – RR k2), for instance, with k2 = 0.5, k1 = 0.360 for males and 0.353 for females, or with k2 = 0.42, k1 = 0.414 for males and 0.420 for females. With linear scaling, QTa = 460 msec was established as the upper 2% normal limit, with 32 msec as the limit for a significant QTa increase from reference ECG in serial comparison. Conclusion: Traditional procedures for establishment of normal limits failed because of proportional scaling, assumption of normal QT distribution, or omission of regression intercept. Percentile distributions of linearly scaled adjusted QT produced regularized rate invariant normal limits within normal sinus rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2002.01211.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
RAUTAHARJU, P. M., & ZHANG, Z.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2002-12
Volume
13
Issue
12
Pages
1211-1218
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2079200162
Cited by
117
References
0
FWCI
3.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Linearly Scaled, Rate‐Invariant Normal Limits for QT Interval: Eight Decades of Incorrect Application of Power Functions. https://app.cochat.ai/papers/10.1046/j.1540-8167.2002.01211.x
The paper
RAUTAHARJU, P. M., & ZHANG, Z. (2002). Linearly Scaled, Rate‐Invariant Normal Limits for QT Interval: Eight Decades of Incorrect Application of Power Functions. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2002.01211.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.