CoChat

Characterization of Sustained Atrial Tachycardia in Dogs with Rapid Ventricular Pacing‐Induced Heart Failure

Stambler, Bruce S., Fenelon, Guilherme, Shepard, Richard K., Clemo, Henry F., Guiraudon, Colette M. · 2003 · Journal of Cardiovascular Electrophysiology
Cited by 122

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: Atrial arrhythmias often complicate congestive heart failure (CHF). We characterized inducible atrial tachyarrhythmias and electrophysiologic alterations in dogs with CHF and atrial enlargement produced by rapid ventricular pacing. Methods and Results: Endocardial pacing leads were implanted in the right ventricle, right atrium, and coronary sinus in 18 dogs. The right ventricular lead was connected to an implanted pacemaker capable of rapid ventricular pacing. The atrial leads were used to perform electrophysiologic studies in conscious animals at baseline in all dogs, during CHF induced by rapid ventricular pacing at 235 beats/min in 15 dogs, and during recovery from CHF in 6 dogs. After 20 ± 7 days of rapid ventricular pacing, inducibility of sustained atrial tachycardia (cycle length 120 ± 12 msec ) was enhanced in dogs with CHF. Atrial tachycardia required a critical decrease in atrial burst pacing cycle length (≤130 msec) for induction and often could be terminated by overdrive pacing. Calcium antagonists (verapamil, flunarizine, ryanodine) terminated atrial tachycardia and suppressed inducibility. Effective refractory periods at 400‐ and 300‐msec cycle lengths in the right atrium and coronary sinus were prolonged in dogs with CHF. Atrial cells from dogs with CHF had prolonged action potential durations and reduced resting potentials and delayed afterdepolarizations (DADs). Mitochondria from atrial tissue from dogs with CHF were enlarged and had internal cristae disorganization. Conclusions: CHF promotes inducibility of sustained atrial tachycardia. Based on the mode of tachycardia induction, responses to pacing and calcium antagonists, and presence of DADs, atrial tachycardia in this CHF model has a mechanism most consistent with DAD‐induced triggered activity resulting from intracellular calcium overload. (J Cardiovasc Electrophysiol, Vol. 14, pp. 499‐507, May 2003)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1540-8167.2003.02519.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 122

Metadata

Authors
Stambler, B. S., Fenelon, G., Shepard, R. K., Clemo, H. F., & Guiraudon, C. M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2003-05
Volume
14
Issue
5
Pages
499-507
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1966709796
Cited by
122
References
1
FWCI
5.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of Sustained Atrial Tachycardia in Dogs with Rapid Ventricular Pacing‐Induced Heart Failure. https://app.cochat.ai/papers/10.1046/j.1540-8167.2003.02519.x
The paper
Stambler, B. S., Fenelon, G., Shepard, R. K., Clemo, H. F., & Guiraudon, C. M. (2003). Characterization of Sustained Atrial Tachycardia in Dogs with Rapid Ventricular Pacing‐Induced Heart Failure. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2003.02519.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.