The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Combined Efficacy of Atrial Septal Lead Placement and Atrial Pacing Algorithms for Prevention of Paroxysmal Atrial Tachyarrhythmia
Abstract
Introduction: The combined role of atrial septal lead location and atrial pacing algorithms in the prevention of atrial tachyarrhythmias (AT/AF), including both atrial fibrillation and flutter, is unknown. We tested the hypothesis that atrial prevention pacing algorithms could decrease AT/AF frequency in patients with atrial septal leads, bradycardia, and paroxysmal AT/AF. Methods and Results: A total of 298 patients (age 70 ± 10 years; 61% male) from 35 centers were implanted with a DDDRP pacing system including three AT/AF prevention pacing algorithms. Lead site was randomized at implant to right atrial septal or nonseptal. Patients were randomized 1 month postimplant to AT/AF prevention ON or OFF for 3 months and then crossed over for 3 months. Patients logged symptomatic AT/AF episodes via a manual activator. Prevention efficacy was evaluated based on intention‐to‐treat in 277 patients (138 septal) with complete follow‐up. No changes in device‐recorded AT/AF frequency or burden were observed with algorithms OFF versus ON or between patients randomized to septal versus nonseptal lead location. Analysis of other secondary outcomes revealed that AT/AF prevention pacing resulted in decreased atrial premature contractions in both the septal (1.9 [0.2–8.7] vs 3.3 [0.3–10.6]× 10 3/day; P < 0.01) and nonseptal groups (0.9 [0.2–3.3] vs 1.3 [0.3–5.5]× 10 3/day; P < 0.001). Patients with septal leads had fewer symptomatic AT/AF episodes ON versus OFF (1.4 ± 3.0 vs 2.5 ± 5.2/month, P = 0.01). Conclusion: The combination of three atrial prevention pacing algorithms did not decrease device classified atrial tachyarrhythmia frequency or burden during a 3‐month cross‐over period in bradycardic patients and septal or nonseptal atrial pacing leads. Prevention pacing was associated with decreased frequency of premature atrial contractions and with decreased symptomatic atrial tachyarrhythmia frequency in patients with atrial septal leads. (J Cardiovasc Electrophysiol, Vol. 14, pp. 1189‐1195, November 2003)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627
Saksena, S., Prakash, A., Ziegler, P., Hummel, J. D., Friedman, P., Plumb, V. J., Wyse, D. G., Johnson, E., Fitts, S., & Mehra, R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02068-5 · Cited by 171
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Metadata
- Authors
- PADELETTI, L., PÜRERFELLNER, H., ADLER, S. W., WALLER, T. J., HARVEY, M., HORVITZ, L., HOLBROOK, R., KEMPEN, K., MUGGLIN, A., HETTRICK, D. A., & Worldwide ASPECT Investigators
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 14
- Issue
- 11
- Pages
- 1189-1195
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2094196263
- Cited by
- 177
- References
- 4
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Efficacy of Atrial Septal Lead Placement and Atrial Pacing Algorithms for Prevention of Paroxysmal Atrial Tachyarrhythmia. https://app.cochat.ai/papers/10.1046/j.1540-8167.2003.03191.x
- The paper
- PADELETTI, L., PÜRERFELLNER, H., ADLER, S. W., WALLER, T. J., HARVEY, M., HORVITZ, L., HOLBROOK, R., KEMPEN, K., MUGGLIN, A., HETTRICK, D. A., & Worldwide ASPECT Investigators. (2003). Combined Efficacy of Atrial Septal Lead Placement and Atrial Pacing Algorithms for Prevention of Paroxysmal Atrial Tachyarrhythmia. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2003.03191.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.