Enhanced Detection of Arrhythmia Vulnerability Using T Wave Alternans, Left Ventricular Ejection Fraction, and Programmed Ventricular Stimulation: A Prospective Study in Subjects with Chronic Ischemic Heart Disease
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Introduction: In previous studies, the prognostic value of T wave alternans (TWA) was similar to that of programmed ventricular stimulation (PVS). However, presently it is unclear if TWA and PVS identify the same patients or provide complementary risk stratification information. In addition, the effects of left ventricular ejection fraction (LVEF) on the prognostic value of TWA are unknown. The aim of this study was to determine if combined assessment of TWA, LVEF, and PVS improves arrhythmia risk stratification. Methods and Results: This was a prospective study of 144 patients with coronary artery disease and LVEF ≤40% who were referred for PVS for standard clinical indications. The endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator (ICD) therapy. TWA (hazard ratio 2.2, P = 0.03) and PVS (hazard ratio 1.9, P = 0.05) both were significant predictors of endpoint events, and TWA was the only independent predictor. LVEF markedly influenced the prognostic value of TWA, which was a potent predictor of events in subjects with LVEF between 30% and 40% (event rates: TWA+ 36%, TWA‐ 0%, P = 0.001) but did not predict events in subjects with LVEF <30% (hazard ratio 1.1, P > 0.5). PVS successfully identified additional low‐risk patients within the cohort with negative or indeterminate TWA results (hazard ratio 4.7, P = 0.015) but did not provide incremental prognostic information for TWA+ patients (hazard ratio 0.9, P > 0.5). Conclusion: The combined use of TWA, LVEF, and PVS is a promising new approach to arrhythmia risk stratification that permits identification of high‐risk and very‐low‐risk patients. (J Cardiovasc Electrophysiol, Vol. 15, pp. 170‐176, February 2004)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Pires, L. A., Lehmann, M. H., Buxton, A. E., Hafley, G. E., & Lee, K. L. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01482-6 · Cited by 42
Cited by
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.003 · Cited by 428
Verrier (2011) · doi:10.1016/j.jacc.2011.06.029 · Cited by 421
“(44) 144 patients with CAD and LVEF 40% 28 7% 2.”
T-Wave Alternans and the Susceptibility to Ventricular Arrhythmias
Narayan, S. M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.066 · Cited by 357
Microvolt T-Wave Alternans for the Risk Stratification of Ventricular Tachyarrhythmic Events
Gehi, A. K., Stein, R. H., Metz, L. D., & Gomes, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.059 · Cited by 252
Metadata
- Authors
- RASHBA, E. J., OSMAN, A. F., MACMURDY, K., KIRK, M. M., SARANG, S. E., PETERS, R. W., SHOROFSKY, S. R., & GOLD, M. R.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2004-02
- Volume
- 15
- Issue
- 2
- Pages
- 170-176
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1984400720
- Cited by
- 64
- References
- 4
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Detection of Arrhythmia Vulnerability Using T Wave Alternans, Left Ventricular Ejection Fraction, and Programmed Ventricular Stimulation: A Prospective Study in Subjects with Chronic Ischemic Heart Disease. https://app.cochat.ai/papers/10.1046/j.1540-8167.2004.03428.x
- The paper
- RASHBA, E. J., OSMAN, A. F., MACMURDY, K., KIRK, M. M., SARANG, S. E., PETERS, R. W., SHOROFSKY, S. R., & GOLD, M. R. (2004). Enhanced Detection of Arrhythmia Vulnerability Using T Wave Alternans, Left Ventricular Ejection Fraction, and Programmed Ventricular Stimulation: A Prospective Study in Subjects with Chronic Ischemic Heart Disease. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1046/j.1540-8167.2004.03428.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.