The DOI matches its Crossref record.
Robust whitening procedure in blind source separationcontext
Abstract
An efficient algorithm is presented for robust whitening in the presence of temporally uncorrelated additive noise that may be spatially correlated. This whitening is introduced as a pre-processing step in the blind source separation process. The robust whitening consists in the eigenvalue decomposition of a positive definite linear combination of a set a correlation matrices taken at nonzero lags. The coefficients of the linear combination are computed by a finite step global convergence algorithm. Some numerical simulations are provided to illustrate the effectiveness of the solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adaptive Blind Signal and Image Processing: Learning Algorithms and Applications
Cichocki, A., & Amari, S. (2002) · Wiley eBooks · doi:10.1002/0470845899 · Cited by 1,863
Self-citationDelorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759
Independent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Barbati, G., Porcaro, C., Zappasodi, F., Rossini, P. M., & Tecchio, F. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.015 · Cited by 293
Metadata
- Authors
- Belouchrani, A., & Cichocki, A.
- Venue
- Electronics Letters
- Published
- 2000-11-23
- Volume
- 36
- Issue
- 24
- Pages
- 2050-2051
- ISSN
- 0013-5194 (ISSN-L)
- 1350-911X
- OpenAlex
- W2151544690
- Cited by
- 178
- References
- 0
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust whitening procedure in blind source separationcontext. https://app.cochat.ai/papers/10.1049/el:20001436
- The paper
- Belouchrani, A., & Cichocki, A. (2000). Robust whitening procedure in blind source separationcontext. Electronics Letters. https://doi.org/10.1049/el%3A20001436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.