Cited by 1,759EEG and Brain-Computer InterfacesBlind Source Separation TechniquesTensor decomposition and applications

Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis

Open access
Delorme, Arnaud, Sejnowski, Terrence, Makeig, Scott·2007·NeuroImage

Abstract

Detecting artifacts produced in EEG data by muscle activity, eye blinks and electrical noise is a common and important problem in EEG research. It is now widely accepted that independent component analysis (ICA) may be a useful tool for isolating artifacts and/or cortical processes from electroencephalographic (EEG) data. We present results of simulations demonstrating that ICA decomposition, here tested using three popular ICA algorithms, Infomax, SOBI, and FastICA, can allow more sensitive automated detection of small non-brain artifacts than applying the same detection methods directly to the scalp channel data. We tested the upper bound performance of five methods for detecting various types of artifacts by separately optimizing and then applying them to artifact-free EEG data into which we had added simulated artifacts of several types, ranging in size from thirty times smaller (-50 dB) to the size of the EEG data themselves (0 dB). Of the methods tested, those involving spectral thresholding were most sensitive. Except for muscle artifact detection where we found no gain of using ICA, all methods proved more sensitive when applied to the ICA-decomposed data than applied to the raw scalp data: the mean performance for ICA was higher and situated at about two standard deviations away from the performance distribution obtained on raw data. We note that ICA decomposition also allows simple subtraction of artifacts accounted for by single independent components, and/or separate and direct examination of the decomposed non-artifact processes themselves.

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2006.11.004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ICA was used to isolate and remove muscle and eye artifacts to assess whether the increased gamma band power in meditators was due to muscle or eye activity.

    “In order to assess whether the increased power in the gamma band we observed in meditators was due to muscle or eye activity, we used the ICA algorithm to isolate and remove these artifacts [45].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Delorme, A., Sejnowski, T., & Makeig, S.
Affiliations
University of California San Diego (US)
Venue
NeuroImage
Publisher
Elsevier BV
Published
2007-02
Volume
34
Issue
4
Pages
1443-1449
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2149407814
Cited by
1,759
References
1
Citations by year
2026: 97 · 2025: 113 · 2024: 113 · 2023: 139 · 2022: 118 · 2021: 126 · 2020: 120 · 2019: 122 · 2018: 138 · 2017: 108 · 2016: 94 · 2015: 94 · 2014: 85 · 2013: 60 · 2012: 69
FWCI
18.37
Type
journal article
Language
en
Open access
Locations
  • NeuroImage (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • HAL (submittedVersion)
Funders
  • Howard Hughes Medical Institute
  • Institut national de recherche en informatique et en automatique (INRIA)
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke (R01NS047293)
  • National Center for Research Resources (RR13651-01A1)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Computer Science › Signal Processing › Blind Source Separation Techniques
  • Physical Sciences › Mathematics › Computational Mathematics › Tensor decomposition and applications
Keywords
EEG artifact detection, independent component analysis, higher-order statistics, muscle artifacts, eye blink artifacts, electronic noise, Infomax, second-order blind identification, FastICA, simulated EEG data
MeSH terms
Algorithms, Automation, Computer Simulation, Electroencephalography, Humans, Sensitivity and Specificity, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review