Modular digital twin modelling method for 10 kV cable lines based on real‐time temperature field inversion
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
State perception of long‐span 10 kV cable lines is one of the critical issues in building intelligent distribution networks. Digital twin (DT), which can map the physical status of equipment in real‐time, has received extensive attention. However, traditional modelling methods cannot meet the requirement of long‐span complex DT's real‐time computation and scalability. In order to reduce the modelling cost and improve the calculation speed, a modular DT modelling method for cable lines based on real‐time temperature field inversion is proposed. The authors develop a modular reduced‐order modelling method that applies to long‐span 10 kV cable lines. Combined with the temperature field inversion, a DT inversion algorithm is proposed to evaluate the transient temperature field and contact resistance inside cable lines, which has been used to evaluate the emergency load capacity. Finally, temperature rise tests verified the DT inversion algorithm's correctness. The operating status of cable lines was evaluated through the modular DT, and the emergency time and emergency ampacity were calculated. The result shows that the new method meets the real‐time and high‐precision requirements of DT calculation in actual operation scenarios. It can be easily extended to cable lines of different voltage levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Within the high-voltage apparatus community, accelerated temperature-field surrogates have been reported for power transformers18, bushings19, cable lines20, and GIS21,22.”
From Uncertainty-aware temperature field reconstruction from sparse samples and sensing via latent-space enhancement for GIS digital twin applications (2026) · cites this paper as [20]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital twin: values, challenges and enablers from a modeling perspective
Rasheed, A., San, O., & Kvamsdal, T. (2020) · IEEE Access · doi:10.1109/access.2020.2970143 · Cited by 1,952
Tao, F., Xiao, B., Qi, Q., Cheng, J., & Ji, P. (2022) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2022.06.015 · Cited by 1,255
Digital Twin: Values, Challenges and Enablers
Rasheed, A., San, O., & Kvamsdal, T. (2019) · arXiv · doi:10.48550/arxiv.1910.01719 · Cited by 81
Research works printed but not linked: 35
- 10.1049/hve.2016.0005 · DOI · Paper page
- 10.1049/hve2.12317 · doi:10.1049/hve2.12317
- 10.1049/hve2.12089 · doi:10.1049/hve2.12089
- 10.1049/hve2.12318 · doi:10.1049/hve2.12318
- 10.1016/j.ymssp.2022.109471 · doi:10.1016/j.ymssp.2022.109471
- 10.1109/tpwrd.2013.2263300 · doi:10.1109/tpwrd.2013.2263300
- 10.1016/j.isatra.2019.05.011 · DOI · Paper page
- 10.1016/j.oceaneng.2019.05.045 · DOI · Paper page
- 10.1016/j.ijhydene.2020.10.108 · DOI · Paper page
- 10.1016/j.egyai.2020.100004 · DOI · Paper page
- 10.1016/j.compind.2021.103586 · DOI · Paper page
- 10.1016/j.engfailanal.2020.104517 · DOI
- 10.1016/j.infsof.2022.107008 · DOI · Paper page
- 10.1016/j.autcon.2020.103547 · DOI · Paper page
- 10.1049/hve2.12260 · DOI
- 10.1109/tii.2021.3115119 · DOI · Paper page
- 10.1016/j.ress.2022.108874 · DOI
- 10.1016/j.proci.2020.06.045 · DOI
- 10.1016/j.applthermaleng.2019.04.083 · doi:10.1016/j.applthermaleng.2019.04.083
- 10.1016/j.ijepes.2022.108573 · doi:10.1016/j.ijepes.2022.108573
- 10.1016/j.applthermaleng.2023.120237 · DOI
- 10.1109/access.2020.3005305 · doi:10.1109/access.2020.3005305
- 10.1049/hve.2017.0037 · DOI
- 10.1016/j.applthermaleng.2013.09.002 · doi:10.1016/j.applthermaleng.2013.09.002
- 10.1016/j.applthermaleng.2015.10.076 · doi:10.1016/j.applthermaleng.2015.10.076
- 10.1016/j.rcim.2019.101895 · DOI · Paper page
- 10.1109/tpwrd.2013.2296912 · doi:10.1109/tpwrd.2013.2296912
- 10.1016/j.ijheatmasstransfer.2018.10.059 · doi:10.1016/j.ijheatmasstransfer.2018.10.059
- 10.1063/1.5124516 · DOI
- 10.1016/j.jcp.2013.02.028 · DOI · Paper page
- 10.1007/bf00281557 · doi:10.1007/bf00281557
- 10.1007/s00158‐018‐1925‐3 · DOI
- Wang P.Y. et al.:Dynamic thermal analysis of high‐voltage power cable insulation for cable dynamic thermal rating. IEEE Access 7 56095–56106 (2019).https://doi.org/10.1109/access.2019.2913704 · doi:10.1109/access.2019.2913704
- 10.1049/hve2.12168 · DOI
- 10.1049/piee.1971.0335 · doi:10.1049/piee.1971.0335
Cited by
Wang, J., Zhou, Z., Chen, W., Liu, B., Su, S., Ding, J., Peng, Z., & Gao, W. (2026) · Scientific Reports · doi:10.1038/s41598-026-52842-8 · Cited by 2
Metadata
- Authors
- Huang, S., & Niu, H.
- Venue
- High Voltage
- Published
- 2024-07-15
- Volume
- 10
- Issue
- 1
- Pages
- 56-68
- ISSN
- 2096-9813
- 2397-7264
- Cited by
- 12
- References
- 3
- Language
- en
- Funders
- National High-Tech Research and Development Program (2015AA050201)
- State Grid Zhejiang Electric Power Company (HDXS3‐2110037)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modular digital twin modelling method for 10 kV cable lines based on real‐time temperature field inversion. https://app.cochat.ai/papers/10.1049/hve2.12465
- The paper
- Huang, S., & Niu, H. (2025). Modular digital twin modelling method for 10 kV cable lines based on real‐time temperature field inversion. High Voltage. https://doi.org/10.1049/hve2.12465
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.