Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch open
The DOI matches its Crossref record.
Abstract
To analyse influences under various fault conditions, a fault model of an inverter-fed permanent magnet (PM) synchronous motor drive that can be used for a performance assessment of a diagnostic algorithm is presented. For fault conditions of a drive system, a short-circuited turn in the stator winding, switching device open in pulse width modulated inverter and the isolation between the inverter and motor are considered. Even though the conventional dq model is widely used to control an AC motor, it cannot be used directly for the analysis of a motor fault, since three-phase balanced condition does not hold under such conditions, and thus, it is not easy to obtain phase voltage inputs of motor from the pole voltage. To overcome this limitation, a fault model of an inverter-fed PM synchronous motor is derived using the line voltage, which can be effectively used to evaluate the performance of a fault detection algorithm. A test motor producing short-circuited turn in the stator winding is built. The validity of the proposed fault model is verified through the comparative simulations and experiments using digital signal processor TMS320F28335 under various fault conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Kim, K.-H. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2060463 · Cited by 184
Self-citationMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“Open-circuit phase faults occur when a phase winding breaks or when an electronic switching device fails [3].”
BackgroundComprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Metadata
- Authors
- Kim, K.-H., Choi, D.-U., Gu, B.-G., & Jung, I.-S.
- Venue
- IET Electric Power Applications
- Published
- 2010-04
- Volume
- 4
- Issue
- 4
- Pages
- 214-225
- ISSN
- 1751-8660 (ISSN-L)
- 1751-8679
- OpenAlex
- W2040432521
- Cited by
- 71
- References
- 0
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch open. https://app.cochat.ai/papers/10.1049/iet-epa.2009.0183
- The paper
- Kim, K.-H., Choi, D.-U., Gu, B.-G., & Jung, I.-S. (2010). Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch open. IET Electric Power Applications. https://doi.org/10.1049/iet-epa.2009.0183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.