Abstract
To detect a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor, a simple online fault detecting scheme is presented. The proposed scheme is based on the monitoring of the second-order harmonic components in theq-axis current through harmonic analysis. To verify the effectiveness of the proposed scheme, a test motor which allows an interturn short in the stator winding has been built, and the entire control system has been implemented using the DSP TMS320F28335.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to the measurement problems, usually measured voltage signal has not been taken as the diagnostic signal; reference or estimated stator vector components (in rotor flux oriented frame, d-q), e.g.[38].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“Torque-producing q-axis current component [38], [182] and a ratio between d-and qaxis components [185] have been applied to design a diagnostic method so far;”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“As in the case of most of the diagnostic methods, the proposed method requires the FFT calculation and thus steady-state operation.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“In [38] the component has been used in order to diagnose the ITSC fault.It is proposed to search for the second-order harmonic amplitude variations and compare it to the healthy condition (the FI is the ratio of 2 nd order harmonic amplitudes in faulty and healthy conditions).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
In the citing paper
“A lot of interest is paid into interpolating the FI according to the actual operating pointthere is a necessity to know the amplitudes of the 2 nd order isq harmonic for idle and rated torques for different speed values (only high speed operation is taken into account).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [38]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345492 · Cited by 264
An unsupervised, on-line system for induction motor fault detection using stator current monitoring
Schoen, R. R., Lin, B. K., Habetler, T. G., Schlag, J. H., & Farag, S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475698 · Cited by 239
Current monitoring for detecting inter-turn short circuits in induction motors
Stavrou, A., Sedding, H. G., & Penman, J. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.911400 · Cited by 168
Online Model-Based Stator-Fault Detection and Identification in Induction Motors
De Angelo, C. H., Bossio, G. R., Giaccone, S. J., Valla, M. I., Solsona, J. A., & Garcia, G. O. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2012468 · Cited by 166
Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847964 · Cited by 87
Kim, K.-H., Choi, D.-U., Gu, B.-G., & Jung, I.-S. (2010) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0183 · Cited by 71
Self-citationStator-Interlaminar-Fault Detection Using an External-Flux-Density Sensor
Romary, R., Jelassi, S., & Brudny, J. F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029525 · Cited by 52
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [38] the component has been used in order to diagnose the ITSC fault.”
BackgroundMethodInfluentialEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Metadata
- Authors
- Kim, K.-H.
- Affiliations
- Seoul National University of Science and Technology (KR)
- Corresponding author
- Kim, Kyeong-Hwa
- ORCID
- Kim, Kyeong-Hwa
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-06
- Volume
- 58
- Issue
- 6
- Pages
- 2565-2568
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2121565094
- Cited by
- 184
- References
- 9
- Citations by year
- 2026: 6 · 2025: 19 · 2024: 19 · 2023: 16 · 2022: 21 · 2021: 18 · 2020: 12 · 2019: 13 · 2018: 9 · 2017: 9 · 2016: 11 · 2015: 8 · 2014: 11 · 2013: 6 · 2012: 5
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- stator winding faults, permanent magnet synchronous motor, real-time fault detection, second harmonic, q-axis current, DSP-based motor control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring. https://app.cochat.ai/papers/10.1109/tie.2010.2060463
- The paper
- Kim, K.-H. (2011). Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic Monitoring. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2010.2060463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.