The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Method for determining the maximum allowable penetration level of distributed generation without steady-state voltage violations
Abstract
One of the main factors that may limit the penetration level of distributed generation (DG) in typical distribution systems is the steady-state voltage rise. The maximum amount of active power supplied by distributed generators into each system bus without causing voltage violations can be determined by using repetitive power flow studies. However, this task is laborious and usually time-consuming, since different loading level and generation operation modes have to be evaluated. Therefore this article presents a method that, based on only one power flow solution and one matrix operation, can directly determine the maximum power that can be injected by distributed generators into each system bus without leading to steady-state voltage violations. This method is based on the determination of voltage sensitivities from a linearised power system model. In addition, this article proposes a numerical index to quantify the responsibility of each generator for the voltage level rise in a multi-DG system. Based on this index, utility managers can decide which generators, and in which degree, should be penalised by the voltage rise or rewarded by not depreciating the voltage profile. The method is applied to a 70-bus distribution network. The results are compared with those obtained by repetitive power flow solutions in order to validate the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Cited by
A Comprehensive Assessment of PV Hosting Capacity on Low-Voltage Distribution Systems
Torquato, R., Salles, D., Oriente Pereira, C., Meira, P. C. M., & Freitas, W. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2798707 · Cited by 270
Self-citationProbabilistic hosting capacity for active distribution networks
Al-Saadi, H., Zivanovic, R., & Al-Sarawi, S. F. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2698505 · Cited by 124
Maximum PV generation estimation method for residential low voltage feeders
Heslop, S., MacGill, I., & Fletcher, J. (2016) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2016.06.003 · Cited by 37
Metadata
- Authors
- Ayres, H. M., Freitas, W., De Almeida, M. C., & Da Silva, L. C. P.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2010-04
- Volume
- 4
- Issue
- 4
- Pages
- 495-508
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2064884483
- Cited by
- 172
- References
- 1
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method for determining the maximum allowable penetration level of distributed generation without steady-state voltage violations. https://app.cochat.ai/papers/10.1049/iet-gtd.2009.0317
- The paper
- Ayres, H. M., Freitas, W., De Almeida, M. C., & Da Silva, L. C. P. (2010). Method for determining the maximum allowable penetration level of distributed generation without steady-state voltage violations. IET Generation, Transmission & Distribution. https://doi.org/10.1049/iet-gtd.2009.0317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.